Device Purpose

Rapid NCCT Stroke is an AI-powered software designed to expedite the triage of suspected Intracranial Hemorrhage and Large Vessel Occlusion in adult stroke patients by analyzing non-enhanced head CT scans. It utilizes specialized algorithms for ICH detection and a combination of ASPECTS and Hyperdense Vessel Sign analysis for LVO suspicion, aiming to provide rapid notifications to clinicians and improve workflow efficiency in time-sensitive stroke care.

Summary

Rapid NCCT Stroke is a radiological computer-aided triage and notification software designed to analyze nonenhanced head CT (NCCT) images for adult patients. Its primary purpose is to assist hospital networks and trained clinicians in prioritizing workflow by flagging and communicating suspected findings of Intracranial Hemorrhage (ICH) and Large Vessel Occlusion (LVO) in the ICA and MCA-M1 regions directly from NCCT scans. The system employs an artificial intelligence algorithm, operating within the integrated Rapid Platform, to analyze these images. For ICH detection, it utilizes a dedicated ICH algorithm, while LVO suspicion is determined through a combined analysis of ASPECTS and Hyperdense Vessel Sign (HVS) algorithms. Notifications of suspected positive cases are delivered via PACS, email, or mobile devices, including compressed preview images intended for informational and triage purposes only, not for primary diagnosis. Performance of Rapid NCCT Stroke was evaluated in a retrospective, multicenter study involving 254 cases. The device demonstrated high sensitivity (0.962) and specificity (0.974) for ICH detection. For LVO detection on NCCT, the software achieved a sensitivity of 0.635 and specificity of 0.951, and also showed non-inferiority to expert readers and superiority to non-expert readers in LVO triage. A significant advantage highlighted is the rapid notification time, averaging 2.5 minutes, compared to the standard care's mean image review initiation time of 58.72 minutes. Although LVO detection sensitivity on NCCT is inherently lower than on CTA, the device aims to expedite initial LVO suspicion, with cautions that CTA or MRA remains crucial for definitive stroke workup and that the device is not for ruling out LVO. Subgroup analyses across different demographics and scanner types were conducted, with the device consistently aiming to improve time-to-notification for critical stroke findings.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

NCCTIntracranial HemorrhageLarge Vessel OcclusionArtificial IntelligenceTriage SoftwareStroke WorkflowImage AnalysisNotification SystemASPECTSHyperdense Vessel Sign

Device Metadata

Submission Number
K222884
Company
iSchemaView, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. Considering the LVO sensitivity of 0.635 on NCCT, what specific training data and algorithmic features allow the software to differentiate subtle early ischemic changes (ASPECTS) and hyperdense vessel signs from common NCCT artifacts or mimics that could lead to false positives or negatives?; The document reports lower LVO detection performance on Philips and Siemens scanners. What were the root causes identified for this variability, and what ongoing or planned model adjustments or site-specific calibrations are recommended to ensure equitable performance across different imaging hardware?; How does the system handle cases with 'Hemorrhagic Transformation' or 'Hematoma' listed under 'Contraindications/Exclusions,' given these are often critical findings the software is designed to detect (ICH) or might co-exist with LVO? Does this imply it won't process these scans or flags them differently?; The limitation for Rapid ICH is ≥ 0.4ml. What is the clinical significance of missing hemorrhages smaller than 0.4ml in the context of initial triage, and how does this threshold compare to the detection capabilities of human readers in emergent settings?; Beyond time-to-notification, has any data been collected on the software's impact on downstream clinical decisions, such as time-to-CTA/MRA, time-to-treatment, or reduction in workflow bottlenecks for the LVO pathway, especially considering the caution about not using it as a rule-out device?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, platform)
✓ Detected
HBOMHardware Bill of Materials(hardware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, HBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Rapid NCCT Stroke - iSchemaView, Inc. | ESL FDA AI Device Intelligence