Medscape Medical NewsAll articles

Brainlab Elements Image Fusion, Contouring (4.5);Image Fusion  (4.5);Fibertracking (2.0);BOLD MRI Mapping  (1.0);Image Fusion Angio  (1.0)

Brainlab AG • Radiology • 07/14/2023

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

Brainlab Elements 6.0 is a comprehensive medical image processing software suite designed to enhance image-guided surgery and radiation treatment planning by providing tools for advanced image co-registration, segmentation, DTI fibertracking, BOLD MRI mapping, and cerebrovascular image analysis. The system employs sophisticated algorithms, including a new AI-driven Convolutional Neural Network for tumor identification, and has undergone verification and pre-clinical validation to ensure its performance, safety, and usability in clinical settings.

Summary

Brainlab Elements 6.0 is a suite of software applications designed for processing medical image data to support image-guided surgery and radiation treatment planning. It facilitates the transfer of DICOM data and includes modules for 2D/3D image viewing, processing, co-registration, segmentation, and 3D visualization. Key components include: Elements Contouring for outlining and manipulating anatomical structures from image data (outputting 3D DICOM segmentation objects); Elements Image Fusion for aligning anatomical structures through co-registration of various imaging modalities (CT, MRI, PET, SPECT, US) using rigid and deformable methods; Elements Fibertracking for processing and visualizing cranial white matter tracts from DTI data; Elements BOLD MRI Mapping for analyzing task-based BOLD MRI data to visualize neural activation signals; and Elements Image Fusion Angio for co-registering cerebrovascular image data, such as fusing 2D DSA with MRA/CTA/3D DSA to combine flow and location information. The system incorporates advanced image processing algorithms, including a significant update with an AI/ML-based feature for identifying previously diagnosed lesions or tumors in T1-weighted contrast-enhanced MR images. This Convolutional Neural Network (CNN), developed via supervised learning, complements a pre-existing non-ML tumor segmentation algorithm and is preferred when suitable MR volumes are available. New functionalities, such as automatic fusion of US to MR images in Image Fusion and optional distortion correction in BOLD MRI Mapping, have been introduced. The system's performance and safety were established through comprehensive software verification (integration tests, unit tests, cybersecurity checks) and pre-clinical validation activities. These validations confirmed that the device provides state-of-the-art features for pre-surgical and radiotherapy planning, meets safety and performance requirements with adequate risk mitigation, and offers clinical benefits that outweigh potential risks, with usability affirmed for the intended user group.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Medical Image ProcessingImage-Guided SurgeryRadiation Treatment PlanningImage Co-registrationImage SegmentationDiffusion Tensor Imaging (DTI)BOLD MRI MappingCerebrovascular ImagingArtificial Intelligence (AI)Convolutional Neural Network (CNN)

Device Metadata

Submission Number
K223106
Company
Brainlab AG
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the new AI/ML-based tumor segmentation algorithm (CNN) compare quantitatively to the previous non-ML algorithm and to other state-of-the-art segmentation methods in terms of accuracy, sensitivity, and specificity on diverse datasets?; What specific image characteristics or data quality thresholds determine when the AI/ML algorithm is "preferred" over the non-ML tumor segmentation algorithm for T1+C MR volumes?; Can the Brainlab Elements Fibertracking module integrate with functional data (e.g., from BOLD MRI Mapping) to provide a more comprehensive map of eloquent brain areas and their connectivity for surgical planning?; What are the computational performance metrics (e.g., processing time, memory usage) for the deformable registration methods in Image Fusion, particularly when handling large or multiple volumetric datasets?; How does the system ensure the accuracy and reliability of co-registering 2D DSA sequences with 3D volumetric data (MRA, CTA, 3D DSA) in Image Fusion Angio, given the inherent dimensional differences and potential for projection errors?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, connectivity)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Brainlab Elements Image Fusion, Contouring (4.5);Image Fusion  (4.5);Fibertracking (2.0);BOLD MRI Mapping  (1.0);Image Fusion Angio  (1.0) - Brainlab AG | ESL FDA AI Device Intelligence