AIRAscore
AIRAmed GmbH • Radiology • 08/25/2023
Device Purpose
AIRAscore is a software medical device utilizing convolutional neural networks to automate the segmentation and volumetric quantification of brain structures, including white matter lesions, from MR images. It aims to provide clinicians with objective, standardized data by comparing patient-specific brain volumes and lesion characteristics against an age- and sex-adjusted reference collective, thereby supporting diagnostic workflows in neuroimaging.
Summary
AIRAscore is a software solution designed for the automated analysis of Magnetic Resonance (MR) brain images, offering rapid and reliable segmentation of key brain structures. It identifies and quantifies gray matter, white matter, cerebrospinal fluid, and, when present, white matter lesions, along with providing an additional classification of tissue anatomy. The system features two primary functions: "AIRAscore structure," which delivers volumetric measurements for segmented anatomical regions, including raw values, relative volumes to total intracranial capacity, and percentile comparisons against a reference population, and "AIRAscore MS," which further provides detailed information on the number, volume, and specific categorization (juxtacortical, periventricular, or infratentorial) of white matter lesions. The methodology involves processing DICOM-compliant T1-weighted (and optionally FLAIR) MR images from a single time point using specialized, static convolutional neural networks (CNNs) for segmentation. These results are then corrected for head size and statistically compared against an age- and sex-adjusted reference collective. AIRAscore, operating as a Software as a Service (SaaS) on internal servers, generates comprehensive DICOM reports detailing these volumetric findings and statistical classifications, as well as annotated DICOM images for visual inspection by expert clinicians, thereby aiming to automate and standardize the quantification process. Validation has reportedly confirmed its performance across diverse patient populations and scanner manufacturers.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of AIRAscore's static neuronal networks compare to approaches using dynamically updated or continuously learning models, particularly in diverse patient populations or with evolving imaging protocols?; What is the statistical methodology and composition of the 'age- and sex-adjusted reference collective' used for percentile ranking, and how sensitive are the results to variations within this reference set?; Could the AIRAscore MS function be expanded to quantify other lesion characteristics beyond number, volume, and location (e.g., lesion activity, new vs. old lesions) if appropriate MR sequences were incorporated?; What specific performance metrics (e.g., Dice coefficient, Jaccard index, sensitivity, specificity) were achieved for the segmentation of different brain structures, especially for challenging cases like small or atypically located white matter lesions?; How does AIRAscore handle MR image artifacts or variations in image quality across different scanners and acquisition parameters, and what are the pre-processing steps involved before segmentation?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly