BrainInsight
Hyperfine, Inc. • Radiology • 12/16/2022
Device Purpose
BrainInsight™ is an automated software tool that processes low-field (0.064 T) MR images to provide quantitative measurements of brain structures. It employs machine learning algorithms for tasks such as segmentation of the whole brain and lateral ventricles, and calculation of midline shift, delivering reports and annotated images for clinical review.
Summary
BrainInsight™ is a fully automated medical software designed for the post-processing of Magnetic Resonance (MR) images, specifically to aid clinicians in assessing low-field (0.064 T) structural MRIs. Its primary function is to provide automatic labeling, spatial measurement, and volumetric quantification of various brain structures. The system operates using a proprietary internal pipeline based on machine learning tools, which processes 3D MRI series including T1 Gray/White, T2-weighted, T2-Fast, and FLAIR images. BrainInsight delivers its output as annotated and segmented images in standard formats, complete with color overlays and detailed reports, which can be viewed on third-party workstations and Picture Archive and Communications Systems (PACS). The software is indicated for several applications depending on patient age and image type: midline shift and lateral ventricle analysis for patients aged 2 and older (using T1, T2, T2-Fast, FLAIR sequences), and whole brain segmentation for adults aged 18 and older (using T1 and T2 sequences). Performance evaluations demonstrated the software's accuracy, with midline shift measurements showing mean absolute errors between 0.75 mm and 1.01 mm depending on the MRI sequence. For volumetric segmentation, Dice coefficients for lateral ventricles ranged from 82% to 89% and for whole brain from 95% to 96% when compared to annotator consensus, indicating high accuracy in its quantitative outputs for clinical support.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does BrainInsight's performance with 0.064 T MRI data compare to software analyzing images from higher field strength MRIs, particularly for detecting subtle pathologies?; What are the specific machine learning models and architectures used in BrainInsight's proprietary pipeline, and how do they address potential challenges of low-field image quality?; What is the clinical significance of the reported discrepancies between BrainInsight's measurements (e.g., Dice coefficients, midline shift error) and expert annotators, especially in borderline cases?; How robust is the software to variations in image acquisition parameters or common artifacts encountered in low-field MRI, beyond the specified protocols?; Are there plans to expand BrainInsight's capabilities to include other brain structures, pathologies, or quantitative metrics relevant to low-field MRI analysis?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly