Ceribell Status Epilepticus Monitor

Ceribell, Inc. • Neurology • 05/23/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Ceribell Status Epilepticus Monitor is a software medical device that analyzes EEG data from a proprietary 8-channel headband to automatically detect electrographic status epilepticus (ESE) in adult patients in acute care settings. Its methodology relies on an algorithm applying ACNS Guideline 14 criteria for ESE, demonstrating high sensitivity and specificity in clinical validation, aiming to expedite ESE diagnosis and treatment.

Summary

The Ceribell Status Epilepticus Monitor is a software medical device designed to aid clinicians in diagnosing electrographic status epilepticus (ESE) in adult patients (≥18 years) at risk for seizures within acute-care environments. It functions by analyzing electroencephalogram (EEG) waveforms captured exclusively using the Ceribell Pocket EEG Device and its 10-electrode Instant EEG Headband, which provides an 8-channel bipolar montage. The software's algorithm identifies EEG patterns consistent with ESE, as defined by the American Clinical Neurophysiology Society’s Guideline 14 (electrographic seizures lasting ≥ 10 continuous minutes or ≥ 20% of any 60-minute recording period). The binary output (ESE detected/not detected) is intended as an adjunctive diagnostic tool, to be integrated with other clinical findings, and does not replace comprehensive EEG review by a neurologist for other conditions. The device's performance was evaluated in a retrospective clinical validation study involving 350 adult subjects, comparing its algorithm's findings against a ground truth established by expert neurologists. This study demonstrated high diagnostic accuracy, with the software achieving 100% sensitivity in identifying the 10 ESE-positive cases (no false negatives) and 94% specificity in identifying ESE-negative cases (21 false positives out of 330). Notably, 19 of the 21 false-positive detections were associated with other seizure or epileptiform activity, indicating potential clinical relevance. The device, supported by successful bench-top verification, aims to accelerate ESE diagnosis and thereby reduce delays in initiating time-sensitive treatment in critical care.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Electroencephalograph (EEG)Status Epilepticus (SE)Electrographic Status Epilepticus (ESE)Seizure DetectionSoftware as Medical Device (SaMD)Acute CareDiagnostic AidACNS Guideline 14Clinical ValidationSensitivity and Specificity

Device Metadata

Submission Number
K223504
Company
Ceribell, Inc.
Panel
Neurology
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
diagnosis

Relevant Clinical Questions

  • Q1. Given the 100% sensitivity was observed in a relatively small sample of 10 ESE-positive cases, how might the confidence intervals for sensitivity change with a larger, more diverse ESE-positive cohort, and what is the minimum clinically acceptable sensitivity?; The device uses a specific 10-electrode bipolar montage; how does its ESE detection performance compare to standard, full-montage EEG systems, particularly in detecting subtle or focal ESE manifestations that might be missed by a reduced montage?; Of the 21 false-positive ESE detections, 19 were noted to have other seizures or epileptiform activity. Could the device be further refined or provide nuanced output to differentiate these clinically significant non-ESE events from true negatives or less critical EEG patterns?; The device is intended for acute-care environments and not Epilepsy Monitoring Units. What specific device characteristics or performance limitations underpin this restriction, and could future iterations expand its utility to EMUs?; How does the algorithm account for potential EEG artifacts common in acute care settings (e.g., from patient movement, electrical interference), and what is its robustness in maintaining diagnostic accuracy under such conditions compared to neurologist interpretation?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Ceribell Status Epilepticus Monitor - Ceribell, Inc. | ESL FDA AI Device Intelligence