Medscape Medical NewsAll articles

DeepCatch

MEDICALIP Co., Ltd • Radiology • 06/16/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

DeepCatch is medical imaging software that employs automated algorithms to segment anatomical structures from whole body CT scans, providing quantitative measurements of volume and proportion, along with 3D visualizations. Its scientific basis lies in processing DICOM CT data for accurate anatomical delineation, validated through comprehensive performance testing against ground truth and predicate devices across diverse patient datasets to support clinical assessment.

Summary

DeepCatch is medical image processing software designed to analyze whole body CT images for the automatic segmentation of various anatomical structures, including skin, bone, muscle, visceral fat, subcutaneous fat, internal organs, and the central nervous system. The software processes DICOM-compliant CT data using auto-segmentation algorithms to identify and delineate these tissues. Its primary outputs are quantitative measurements, such as volume and proportions of each structure, delivered as CSV data, and corresponding 3D models for visualization, intended to support clinical assessment and potentially serve as base data for diverse medical applications. The software's efficacy has been established through rigorous non-clinical testing across diverse international datasets (Korean, French, and US-based). Performance evaluations demonstrated high accuracy, with Dice Similarity Coefficients (DSC) for segmentation consistently exceeding 0.900 when compared to ground truth data. Key quantitative outputs, including volumetric and area measurements, showed mean differences of less than ±10% from ground truth, while ratio differences were less than ±1%, and body circumference differences remained below ±5%. Comparative studies against existing predicate devices confirmed that DeepCatch's performance is not inferior, and it exhibited enhanced results in specific areas such as muscle segmentation and certain fat area measurements. The system is designed to be used adjunctively, requiring physician oversight for final confirmation of results.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

CT Image AnalysisAuto-segmentationAnatomical StructuresVolume Calculation3D ModelingVisceral FatSubcutaneous FatMuscle SegmentationDICOMQuantitative Imaging

Device Metadata

Submission Number
K223556
Company
MEDICALIP Co., Ltd
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What specific deep learning architecture or image processing algorithms does DeepCatch utilize for its auto-segmentation, and how were these algorithms trained and validated prior to the performance tests described?; How does the software handle variations in CT image quality, scanner protocols, and patient anatomical abnormalities (e.g., presence of implants or pathological changes) that might affect segmentation accuracy?; The performance tests mention ground truth created by a licensed physician; what was the inter-observer variability in creating these ground truths, and how was this variability accounted for when assessing DeepCatch's accuracy?; Beyond volume and proportion, does DeepCatch offer texture analysis features or other quantitative imaging biomarkers from the segmented regions that could be clinically relevant for conditions like sarcopenia or detailed adiposity assessment?; Given its performance on US, Korean, and French datasets, what is the anticipated generalizability and robustness of DeepCatch's segmentation accuracy across broader global populations and different CT scanner vendors or models not explicitly included in the validation studies?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
DeepCatch - MEDICALIP Co., Ltd | ESL FDA AI Device Intelligence