Medscape Medical NewsAll articles

DeepXray

Alpha Intelligence Manifolds, Inc. • Radiology • 09/08/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

DeepXray is an AI-driven software designed to assist medical professionals by automatically analyzing knee radiographs to quantify joint space width and femoral-tibial angle, and assess osteoarthritis features using Kellgren-Lawrence and OARSI criteria. Its methodology relies on computer vision algorithms trained on a large dataset, with outputs presented in an interactive web report to support, but not replace, clinical judgment in diagnosing knee osteoarthritis.

Summary

DeepXray is a standalone software device employing artificial intelligence and computer vision algorithms to assist trained medical professionals, such as radiologists and orthopedists, in analyzing knee radiographs. It processes either computed (CR) or directly digital (DX) posterior-anterior or anterior-posterior knee images from standing, fixed-flexion views to automatically detect and measure radiographic abnormalities associated with knee osteoarthritis (OA), with the aim of aiding diagnosis without replacing comprehensive patient evaluation or being solely relied upon for diagnostic confirmation. DeepXray provides quantitative measurements including minimum joint space width and the femoral-tibial angle, alongside qualitative assessments of knee OA severity using the Kellgren-Lawrence Grade, and specific features like joint space narrowing, osteophytes, and sclerosis based on OARSI criteria. Its output is presented as an editable web-based summary report, which includes markup images, quality warnings, and an interface for clinicians to review and modify AI-generated results. Performance validation on a large, independent dataset from the Osteoarthritis Initiative (OAI) demonstrated good agreement with expert clinician assessments, achieving sensitivities for various OA indicators between 0.84 and 0.88 and specificities between 0.80 and 0.88, and high accuracy for quantitative measurements, confirming its utility as an adjunctive tool.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

DeepXrayKnee OsteoarthritisArtificial IntelligenceImage Processing SoftwareRadiographsKellgren-Lawrence GradeOARSI CriteriaJoint Space WidthFemoral-Tibial AngleClinical Decision Support

Device Metadata

Submission Number
K223621
Company
Alpha Intelligence Manifolds, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does DeepXray's performance vary across different severities of knee osteoarthritis (e.g., early vs. advanced stages) as defined by Kellgren-Lawrence grades?; What is the impact of the 0.3% of test samples blocked by the automatic quality control mechanism on the overall utility and potential biases of the system in a real-world clinical workflow?; How does the editable web report feature, allowing clinician modification, affect inter-observer variability and the final diagnostic accuracy compared to using the raw AI output alone?; Given the training dataset included images from various X-ray manufacturers, how robust is DeepXray's performance when encountering images from manufacturers not extensively represented or entirely absent in the training data?; What is the typical time saved, if any, by clinicians using DeepXray for knee OA assessment compared to traditional manual review methods, and how does this integrate into existing radiological workflows?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, algorithm, dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
DeepXray - Alpha Intelligence Manifolds, Inc. | ESL FDA AI Device Intelligence