Medscape Medical NewsAll articles

MOZI TPS

Manteia Technologies Co., Ltd. • Radiology • 07/10/2023

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The MOZI TPS is an advanced software system designed to facilitate external beam photon radiotherapy planning by integrating image processing, deep learning-driven automatic structure delineation, and Monte Carlo dose calculation to generate optimized treatment plans. Its methodology centers on providing clinicians with a comprehensive suite of automated and manual tools, with its performance in image registration, contouring accuracy, and dose computation for IMRT/VMAT validated through rigorous testing against established systems and standards.

Summary

The MOZI Treatment Planning System (MOZI TPS) is a standalone software application designed for planning radiotherapy treatments for patients with both malignant and benign diseases, specifically for external beam irradiation using photon beams. Its core functionalities encompass a comprehensive workflow including image processing with automatic rigid and deformable registration, structure delineation utilizing deep learning for automatic contouring of organs at risk, treatment plan design, dose calculation via the Monte Carlo method, plan optimization for techniques like IMRT and VMAT, and subsequent plan evaluation. The system also provides user login, a graphical user interface, and tools for system and patient data management, supporting the DICOM RT standard for interoperability with other radiotherapy equipment and systems. The MOZI TPS employs established algorithms for image registration and incorporates a Monte Carlo based algorithm for photon dose calculation (1MeV-20MeV range), which has been validated for accuracy. Its automatic segmentation capabilities are driven by deep learning models, trained on Chinese datasets and tested on independent US datasets covering various anatomical sites (Head & Neck, Thorax, Abdomen, Pelvis) and demonstrating performance with Dice Similarity Coefficients provided for numerous OARs. Performance testing confirmed its dose calculation, image registration (using NMI and HD metrics), and structure delineation capabilities against predicate and reference devices. Comprehensive end-to-end testing on 18 patient cases, including lung, liver, brain, and Head & Neck cancers using IMRT and VMAT techniques, validated the entire clinical workflow from CT image import to plan export and phantom measurement validation, ensuring the system meets safety (IEC 62083-2009) and performance standards (AAPM TG-119).

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MOZI TPSRadiotherapy PlanningPhoton BeamsMonte Carlo Dose CalculationDeep Learning ContouringImage RegistrationStructure DelineationIMRTVMATDICOM RT

Device Metadata

Submission Number
K223724
Company
Manteia Technologies Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. The document mentions deep learning for automatic contouring and provides Dice Similarity Coefficient (DSC) values for various OARs. What specific deep learning architecture is employed, and how does its performance on particularly challenging cases (e.g., post-operative anatomy or re-irradiation scenarios with altered tissue characteristics) compare to manual contouring by experienced clinicians in terms of both accuracy and time efficiency?; The Monte Carlo dose calculation algorithm is stated to be verified. Could you provide more details on the specific beam modeling parameters, variance reduction techniques utilized, and how its calculation speed for complex IMRT/VMAT plans compares to the predicate's AAA/AXB algorithms without compromising dosimetric accuracy, especially for heterogeneous tissues?; The end-to-end testing involved 18 patient cases for lung, liver, brain, and Head & Neck cancers. Can you elaborate on the diversity of these cases beyond the listed cancer types, specifically concerning tumor stage, patient anatomical variations, the inclusion of motion management strategies, and the complexity of planning objectives (e.g., simultaneous integrated boost, or targets near highly sensitive organs)?; For the deformable image registration, Normalized Mutual Information (NMI) and Hausdorff Distance (HD) were used for evaluation. Beyond these quantitative metrics, what processes or qualitative assessments are in place to validate the clinical plausibility and anatomical correctness of the deformations, especially in regions with significant pathological changes or low image contrast?; The training data for CT structure models was sourced from China, while the testing data was from the United States, with specified demographic and scanner diversity. What specific strategies were implemented during model development and validation to ensure robust generalization across different populations, varied imaging protocols, and potential biases introduced by scanner vendor differences, and were any domain adaptation techniques employed?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, algorithm, dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
MOZI TPS - Manteia Technologies Co., Ltd. | ESL FDA AI Device Intelligence