uOmnispace
Shanghai United Imaging Healthcare Co., Ltd • Radiology • 07/20/2023
Device Purpose
uOmnispace is a comprehensive medical image post-processing software designed to enhance radiological workflows by providing tools for multi-modality image viewing, manipulation, communication, and storage. Its methodology leverages a client-server architecture for remote access and incorporates advanced visualization techniques, including machine learning-based segmentation for features like rib extraction, to support clinical analysis by trained professionals.
Summary
uOmnispace is a medical image post-processing software designed for viewing, manipulating, communicating, and storing medical images from multiple modalities including CT, MRI, PET, and DR. It operates as a software-only solution on standard PC hardware with a client-server architecture, allowing remote multi-user access for trained professionals like physicians and medical technicians. The system supports DICOM formatted images and objects, providing tools for 2D and 3D visualization, annotation, measurement, as well as image filming and reporting capabilities to assist in radiological tasks. It can be used as a standalone system or integrated with other cleared software options and multi-vendor applications. Technologically, uOmnispace offers advanced image processing features such as manual and automatic segmentation, including a machine learning-based algorithm for rib extraction. Its 3D review capabilities encompass Volume Rendering (VR) with Hyper Realistic Rendering (HRR), Multi-Planar Reconstruction (MPR), Maximum/Minimum Intensity Projection (MIP/MinIP), Curved Planar Reformation (CPR), Surface-shaded Display (SSD), and automatic bone removal. The software also provides 3D virtual endoscopy for vessels, airways, and colon. Performance validation for the ML-based rib segmentation algorithm on 60 chest CT scans demonstrated an average DICE score of 0.855, meeting the acceptance criterion of >0.8 and showing consistent performance across different patient subgroups. The system is not intended for displaying digital mammography images for diagnostic purposes in the U.S.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What is the computational performance and scalability of the uOmnispace system when handling large datasets or concurrent multiple users, particularly for its advanced 3D rendering and machine learning-based segmentation features?; How does the "Hyper Realistic Rendering (HRR)" feature specifically enhance diagnostic interpretation compared to standard Volume Rendering, and are there comparative studies validating its clinical benefit?; What are the specific interface requirements for plugging in multi-vendor applications, and how is compatibility and data integrity ensured with these third-party tools?; Beyond rib segmentation, what other anatomical structures or pathologies is the machine learning-based segmentation module being trained or planned for, and what is the development roadmap for these AI-driven tools?; Could you provide more details on the "standard annotation process" for the ground truth data used in the ML algorithm validation, particularly regarding inter-rater variability and the criteria used by the senior clinical specialist for final approval?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, HBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly