Medscape Medical NewsAll articles

Lung-CAD

Imagen Technologies, Inc • Radiology • 10/03/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Lung-CAD is a software device employing deep learning algorithms to analyze adult chest radiographs for signs of lung hyperinflation, presenting findings as DICOM overlays with bounding boxes around regions of interest to assist physicians in concurrent reads. Its scientific basis is validated through performance testing showing high standalone sensitivity and specificity, and clinical studies demonstrating improved reader accuracy when using the device.

Summary

Lung-CAD is a computer-assisted detection (CADe) software device designed to aid physicians in interpreting adult chest radiographs by identifying potential lung hyperinflation. Utilizing deep learning and computer vision techniques, the software analyzes images and, if regions of interest (ROIs) indicative of lung hyperinflation are detected, generates a DICOM Presentation State file. This output overlay includes bounding boxes around the identified ROIs, labeled as "Lung hyperinflation," and can be toggled on or off within a Picture Archiving and Communication System (PACS) viewer. The device is intended as a concurrent reading aid and does not replace the physician's role or other diagnostic tests; it is not for clinical diagnosis of any disease. Performance data for Lung-CAD was established through standalone testing and a clinical reader study. The standalone assessment on 5,000 chest radiograph cases demonstrated high sensitivity (0.898) and specificity (0.894), with an Area Under the Curve (AUC) of the Receiver Operating Characteristic (ROC) curve of 0.964. A multiple reader, multiple case (MRMC) retrospective study involving clinical readers evaluating 244 cases showed that reader accuracy, measured by case-level AUC, was significantly improved when aided by Lung-CAD compared to unaided reads (p-value < 0.001), with an AUC improvement of 0.0632. The software level of concern is Moderate, acknowledging that a malfunction could lead to erroneous diagnosis or delay in care, potentially resulting in minor injury.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Lung-CADComputer-Assisted DetectionChest RadiographLung HyperinflationDeep LearningRegion of InterestDICOMSensitivitySpecificityArea Under the Curve (AUC)

Device Metadata

Submission Number
K230085
Company
Imagen Technologies, Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. Given the standalone Positive Predictive Value of 0.322, what strategies are recommended for clinicians to manage the relatively high number of false positives highlighted by Lung-CAD?; How does the deep learning algorithm differentiate true lung hyperinflation from other conditions that might present similarly on a chest radiograph, such as severe air trapping or bullous disease?; What was the range of experience levels of the clinical readers in the multiple reader, multiple case (MRMC) study, and did the performance improvement with Lung-CAD vary significantly across these different experience levels?; Are there specific patient populations, comorbidities, or image quality variations where Lung-CAD's performance for detecting lung hyperinflation might be less optimal or require additional caution during interpretation?; The Free-Response ROC (FROC) curve terminates at the device’s box-level sensitivity due to the cascaded nature of Lung-CAD predictions; what are the practical implications of this characteristic on its ability to detect all relevant regions of interest?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Lung-CAD - Imagen Technologies, Inc | ESL FDA AI Device Intelligence