Swoop® Portable MR Imaging System

Hyperfine, Inc. • Radiology • 02/22/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Swoop® Portable MR Imaging System™ provides accessible head imaging at the patient's bedside by utilizing low-field magnetic resonance technology. Its methodology centers on deep learning algorithms for superior image reconstruction across various sequences, including newly introduced DWI capabilities, to aid in diagnosis when conventional MRI examinations are not feasible.

Summary

The Swoop® Portable MR Imaging System™ is a bedside magnetic resonance imaging device designed for imaging the internal structure of the head in adult and pediatric patients (≥ 0 years) at the point of care, particularly where full diagnostic examination is not clinically practical. It utilizes a 63.3 mT permanent magnet and a form-fitting head coil to acquire images using standard MRI contrasts. The system is operated via a commercial off-the-shelf tablet which facilitates exam setup, image viewing for quality control, and cloud storage interactions. A significant feature is its image reconstruction algorithm that employs deep learning to enhance image quality for T1W, T2W, and FLAIR sequences by reducing image noise and blurring. This version of the Swoop System incorporates software modifications that introduce a DWI pulse sequence and associated DWI image reconstruction using the Fast Iterative Shrinkage Thresholding Algorithm (FISTA). Additionally, it includes image uniformity correction and enhanced noise correction applicable to all sequence types. Non-clinical performance testing was conducted to ensure these modifications met design specifications and user requirements. This testing included software verification, software validation, and image performance assessments against NEMA and ACR standards, which confirmed the device meets all image quality criteria. Other performance aspects such as biocompatibility, cleaning/disinfection, electrical safety, and cybersecurity were addressed by leveraging existing data from a prior iteration of the device, as the new modifications did not introduce new worst-case scenarios for these aspects.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Portable MRIBedside ImagingNeuroimagingDeep LearningImage ReconstructionDWI (Diffusion-Weighted Imaging)T1W (T1-Weighted)T2W (T2-Weighted)FLAIR (Fluid-Attenuated Inversion Recovery)Point-of-Care

Device Metadata

Submission Number
K230208
Company
Hyperfine, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the image quality of the Swoop System's low-field (63.3 mT) MRI, particularly for the new DWI sequence, compare to conventional high-field MRI systems in detecting specific neuropathologies?; What are the quantitative metrics for the "improved image quality" and "reductions in image noise and blurring" achieved by the deep learning algorithm, especially for T1W, T2W, and FLAIR sequences?; Can the device differentiate between ischemic stroke and hemorrhagic stroke with high sensitivity and specificity using the new DWI and other available sequences at the bedside?; What is the typical acquisition time for a comprehensive head examination using the Swoop system, including T1W, T2W, FLAIR, and DWI sequences, and how does this impact its utility in acute settings?; How does the "image uniformity correction" implemented across all sequence types specifically address potential field inhomogeneities inherent in a portable, low-field magnet design?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Swoop® Portable MR Imaging System - Hyperfine, Inc. | ESL FDA AI Device Intelligence