Saranas Early Bird Bleed Monitoring System

Saranas Inc. • Cardiovascular • 05/25/2023

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Saranas Early Bird Bleed Monitoring System provides a conduit for femoral vascular access and employs bioimpedance technology to detect extravascular fluid accumulation, offering early indication of potential internal bleeding. This version enhances detection accuracy for various bleed rates through an updated algorithm incorporating both impedance drop thresholds and rate-of-change analysis, alongside a new system reset functionality.

Summary

The Saranas Early Bird Bleed Monitoring System is a single-use, sterile medical device designed to facilitate the introduction of catheters and other interventional devices into the femoral artery or vein while maintaining hemostasis during endovascular procedures. Its primary function is to provide physicians with an early warning of potential internal bleeding complications by detecting and monitoring the accumulation of extravascular fluid. The system comprises an introducer sheath with four embedded electrodes, a user interface display (UID), and a compatible dilator. The electrodes connect to a battery-powered impedance analyzer within the UID, which monitors changes in bioimpedance in the tissue surrounding the insertion site. This iteration of the Early Bird system features significant firmware enhancements aimed at improving bleed detection capabilities, particularly for slower bleeds. The detection algorithm has been augmented to include an impedance drop threshold from a baseline value, supplementing the existing slope-based bioimpedance drop rate detection. A Level 1 bleed alert is now triggered by either of these criteria. Additionally, the firmware update includes an improved power-on self-test to reduce false error indications and introduces a user-activated reset function. This reset allows clinicians to re-establish the bioimpedance baseline and restart monitoring, which is particularly useful if the device is dislodged or if bleeding is already active at insertion. The device's physical characteristics, materials, dimensions, and shelf life (now 2 years) remain consistent with the predicate, ensuring no new biocompatibility or mechanical concerns.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

BioimpedanceBleed detectionExtravascular fluidFemoral arteryFemoral veinIntroducer sheathAlgorithm enhancementImpedance drop thresholdEndovascular proceduresHemostasis

Device Metadata

Submission Number
K230273
Company
Saranas Inc.
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the enhanced algorithm's sensitivity and specificity for detecting slow bleeds, using the new impedance drop threshold, compare to the predicate device's slope-based detection in real-world clinical scenarios?; What is the clinical impact of the new reset functionality on managing cases where initial baseline bioimpedance might be skewed or when a re-assessment is needed post-intervention?; Are there quantifiable data on the reduction of false error indications due to the widened upper limit of the calibration self-check during the improved power-on self-test?; Beyond detecting extravascular fluid accumulation, can the bioimpedance data provide any quantitative estimation of the bleed volume or rate?; What specific types of internal bleeding complications (e.g., hematoma, retroperitoneal bleed) is the enhanced algorithm now more adept at detecting compared to the previous version?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials(embedded, firmware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, HBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Saranas Early Bird Bleed Monitoring System - Saranas Inc. | ESL FDA AI Device Intelligence