SKOUT® system

Iterative Scopes Inc. • Gastroenterology-Urology • 04/07/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The SKOUT® system is a computer-aided detection tool utilizing an artificial intelligence algorithm to analyze real-time colonoscopy video, aiming to improve the identification of potential colorectal polyps. Its methodology involves superimposing visual cues on the endoscopic display to assist gastroenterologists, supported by updated hardware for better performance and usability, and software designed for efficient image and error handling.

Summary

The SKOUT® system is a software-based medical device designed to assist gastroenterologists in the real-time detection of potential colorectal polyps during colonoscopy examinations for adult patients undergoing screening or surveillance. It functions as a computer-aided detection (CADe) tool, analyzing high-definition endoscopic video from compatible Olympus and FUJI endoscopes using an artificial intelligence-based algorithm. This algorithm processes the video feed and, upon identifying a suspected polyp, superimposes a blue rectangular outline around the area on the endoscopic monitor, serving as an informational visual aid to enhance the clinician's observational capabilities without replacing their medical judgment. The system's AI algorithm, which forms the core of its detection science, remains consistent with its predicate version. Key operational features include the automatic pausing of polyp detection when surgical tools are present or if lighting is inadequate, preventing procedural interference. The device features an updated single-box hardware architecture for improved component longevity and image quality, alongside software enhancements for better image handling, error management, and overall usability. Non-clinical testing results successfully validated the software, confirmed electrical safety and electromagnetic compatibility, and demonstrated positive human factors outcomes. Performance improvements include a significant reduction in video delay to near-zero (0.0ms for SDI) and no introduction of pixel-level degradation to the endoscopic image.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Colorectal PolypsColonoscopyComputer-Aided Detection (CADe)Artificial Intelligence (AI)Real-time DetectionEndoscopic Video AnalysisGastroenterologyMedical Device SoftwarePolyp DetectionVisual Aid

Device Metadata

Submission Number
K230658
Company
Iterative Scopes Inc.
Panel
Gastroenterology-Urology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the AI algorithm's sensitivity and specificity for polyp detection compare to unassisted colonoscopy, and were there any changes in these metrics due to the hardware and software updates (despite the algorithm itself being unchanged)?; What specific improvements in "image handling" and "error handling" were implemented in the software update, and how do these translate to tangible benefits in clinical workflow or diagnostic accuracy support?; The document states the algorithm is unchanged, implying clinical performance is unchanged. Were any bench or simulated clinical studies performed to confirm that the hardware changes (e.g., single box, updated components) and associated software updates do not inadvertently affect the AI's performance on diverse polyp morphologies or challenging visual conditions?; Given the significant reduction in video delay to 0.0ms (SDI), what technological advancements in the hardware or software architecture enabled this improvement, and how does this near-zero latency enhance the user experience for gastroenterologists?; The system pauses detection when endoscopic tools are present. What is the threshold or method for detecting "inadequate lighting conditions" that also triggers a pause in polyp detection, and how does the system ensure rapid reactivation once conditions are optimal?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials(hardware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, HBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
SKOUT® system - Iterative Scopes Inc. | ESL FDA AI Device Intelligence