Medscape Medical NewsAll articles

AutoContour Model RADAC V3

Radformation, Inc. • Radiology • 04/14/2023

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

AutoContour Model RADAC V3 is a software device utilizing machine learning algorithms to automatically segment anatomical structures on CT and MR medical images for radiation therapy treatment planning. Its methodology involves deep learning models trained on diverse datasets, with performance validated through Dice Similarity Coefficients and qualitative clinical reviews on independent external datasets, demonstrating its utility in assisting treatment planners.

Summary

AutoContour Model RADAC V3 is a software system designed to assist radiation treatment planners by automatically contouring anatomical structures within CT and MR medical images, thereby streamlining preparation for radiation therapy. The system operates by processing DICOM-compliant image data through machine learning algorithms, specifically deep-learning based models. These models are trained on extensive imaging datasets covering various anatomical regions including the head and neck, thorax, abdomen, and pelvis for adult patients. The software comprises a .NET client application for image loading, review, and editing of contours; a local agent service for monitoring new datasets; and a cloud-based service for performing the automatic contouring. This version, RADAC V3, expands upon its predecessor by incorporating 90 new CT models and 11 new MR models for structure segmentation, aiming to improve accuracy and utility in clinical settings. The performance of AutoContour Model RADAC V3 was evaluated through non-clinical testing using independent datasets, distinct from training data, to ensure model generalizability. Validation focused on Dice Similarity Coefficient (DSC) scores and qualitative clinical appropriateness assessed by independent experts. For CT models, training on an average of 373 sets yielded mean DSCs of 0.88 (large structures), 0.88 (medium), and 0.75 (small); external validation on The Cancer Imaging Archive (TCIA) datasets resulted in mean DSCs of 0.90, 0.83, and 0.79 respectively, with an average qualitative clinical rating of 4.5 (out of 5), indicating minor edits needed. MR models, trained on datasets like TCIA GLIS-RT and Prostate-MRI-US-Biopsy, showed training DSCs of 0.87 (medium) and 0.74 (small); external validation on unique datasets produced similar DSCs and an average qualitative rating of 4.4, confirming their clinical utility in assisting with the contouring process.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

AutoContourRadiation TherapyTreatment PlanningMedical ImagingMachine LearningDeep LearningDICOMCTMRIStructure Segmentation

Device Metadata

Submission Number
K230685
Company
Radformation, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of AutoContour RADAC V3, particularly the Dice Similarity Coefficient (DSC) and qualitative review scores, vary across different imaging scanner manufacturers and acquisition protocols not explicitly detailed in the training/testing sets?; What is the observed impact on clinical workflow efficiency (e.g., time saved in contouring) when using AutoContour RADAC V3 compared to manual contouring or previous versions, across different anatomical regions and user experience levels?; Given the demographic data of the training sets (e.g., 84% White for CT), what steps are being taken or planned to ensure the robustness and accuracy of the AI models across more diverse patient populations and rarer anatomical variations?; How do the CT structures generated via post-processing/boolean operations from previously released models (marked 'N/A*' for CNN training) perform in scenarios where the primary models (e.g., Eye, Rib) exhibit lower confidence or accuracy for a specific patient?; What are the specific failure modes or types of inaccuracies most commonly observed in the AI-generated contours for both CT and MR models, and what is the typical user intervention required to correct them according to the qualitative reviews?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, training set, machine learning, deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
AutoContour Model RADAC V3 - Radformation, Inc. | ESL FDA AI Device Intelligence