Medscape Medical NewsAll articles

EW10-EC02 Endoscopy Support Program

FUJIFILM Corporation • Gastroenterology-Urology • 12/15/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EW10-EC02 Endoscopy Support Program is an AI-powered software designed to enhance real-time detection of colonic lesions like polyps and adenomas during colonoscopies using both White Light Imaging and Linked Color Imaging. Its methodology leverages a deep learning algorithm to analyze live endoscopic video and highlight suspicious areas, with clinical trials demonstrating its efficacy in increasing the number of adenomas and polyps detected per colonoscopy when used as an aid by endoscopists.

Summary

The EW10-EC02 Endoscopy Support Program is an artificial intelligence (AI)-driven software designed as a computer-assisted reading tool for endoscopists. Its primary purpose is to aid in the real-time detection of colonic mucosal lesions, such as polyps and adenomas, during standard colonoscopy examinations for both screening and surveillance populations. The system employs a deep learning-based algorithm that analyzes endoscopic video images obtained through standard White Light Imaging (WLI) and Linked Color Imaging (LCI). This computer-aided diagnosis (CAD) technology functions by superimposing visual markers on suspected lesions identified in the live video feed, thereby intending to enhance the physician's visual assessment capabilities without replacing their ultimate clinical judgment. Non-clinical testing of the EW10-EC02 demonstrated high lesion-based sensitivities (95.1% for WLI, 95.5% for LCI) and acceptable false positive rates per patient, with minimal video processing delay attributed to the software. A subsequent multi-center, prospective, randomized controlled trial involving 1,031 subjects compared computer-assisted colonoscopy (CAC) utilizing the EW10-EC02 with conventional colonoscopy (CC). The results indicated that the CAC group achieved a statistically significant increase in Adenoma per Colonoscopy (APC) (0.990 vs 0.849), Polyp per Colonoscopy (PPC) (1.680 vs 1.328), Serrated Lesions per Colonoscopy (SLPC) (0.690 vs 0.475), and Serrated Lesions Detection Rate (SLDR) (35.6% vs 29.1%). While the pre-defined criteria for Positive Predictive Value (PPV) and Positive Percent Agreement (PPA) were met, the absolute values for the CAC group were slightly lower than those for the CC group. The False Positive Rate (FPR) for CAC was determined to be non-inferior to that of CC. Importantly, no significant differences were observed in the rates of adverse events or in colonoscopy withdrawal times between the two study arms.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Artificial IntelligenceColonoscopyPolyp DetectionAdenoma DetectionComputer-Aided DiagnosisReal-time DetectionEndoscopy Support ProgramWhite Light ImagingLinked Color ImagingColonic Lesions

Device Metadata

Submission Number
K230751
Company
FUJIFILM Corporation
Panel
Gastroenterology-Urology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the algorithm's performance differ between White Light Imaging (WLI) and Linked Color Imaging (LCI) in terms of specific lesion morphologies (e.g., flat vs. polypoid) and sizes, beyond the overall sensitivity and false positive rates reported in the non-clinical studies?; Given the slightly lower Positive Predictive Value (PPV) and Positive Percent Agreement (PPA) for the Computer Assisted Colonoscopy (CAC) group in the clinical trial, alongside a non-inferior but numerically higher False Positive Rate (FPR), what is the potential impact on unnecessary biopsies or resections, and how might this be mitigated through endoscopist training or algorithm refinement?; The clinical study noted a statistically significant interaction between screening versus surveillance colonoscopies for the Adenoma per Colonoscopy (APC) endpoint. What specific factors inherent to surveillance procedures (e.g., patient history, expected lesion characteristics) might explain the more pronounced benefit of the EW10-EC02 AI tool in these cases compared to initial screening procedures?; The non-clinical performance testing utilized a dataset from a 100% Asian patient population, while the pivotal clinical trial was conducted in the US with a more diverse racial demographic. Were any sub-analyses performed in the clinical trial to assess if the algorithm's performance (sensitivity, specificity, FPR) varied across different racial or ethnic groups, and how does this inform its generalizability?; What were the specific visual characteristics of the false positives most commonly generated by the EW10-EC02 system during the clinical trial (e.g., mucosal folds, debris, vascular patterns, suction artifacts), and how do these compare in nature and frequency to false positives typically encountered by endoscopists performing conventional colonoscopy without AI assistance?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EW10-EC02 Endoscopy Support Program - FUJIFILM Corporation | ESL FDA AI Device Intelligence