AusculThing ACC
AusculThing Oy • Cardiovascular • 07/12/2023
Device Purpose
The AusculThing ACC is a mobile-based decision support software that utilizes an AI-powered neural network to analyze heart sounds recorded via an electronic stethoscope, assisting healthcare providers in the evaluation of adult and pediatric patients. Its primary function is to automatically differentiate between normal and pathological heart sounds, specifically by detecting the presence of murmurs, with clinical data supporting its comparable performance to predicate devices in terms of accuracy, sensitivity, and specificity.
Summary
The AusculThing ACC is a decision support software designed for healthcare providers to aid in evaluating heart sounds in adult and pediatric patients. It functions by collecting acoustic heart signals via a Thinklabs One electronic stethoscope connected to a mobile device, on which the accompanying app runs; this app guides users in obtaining recordings from various body locations and allows for the phonocardiogram (PCG) data to be analyzed, visualized, and played back. The system's analysis capabilities stem from an AI-based algorithm, specifically a neural network model trained using a proprietary, echocardiogram-validated database of high-quality heart sound recordings. This algorithm automatically analyzes the collected sounds to distinguish between normal and pathological conditions, categorizing heart sounds as 'abnormal' if any murmur is identified or 'normal' if no murmurs or only benign murmurs are found, and provides information on suspected murmurs for abnormal findings. Clinical testing on a cohort of 133 patients (including 84 pediatric and 49 adult subjects, with 84 having confirmed heart defects) demonstrated the device's performance with an accuracy of 92.5%, sensitivity of 90.5%, and specificity of 96.0% in detecting abnormal heart sounds, using echocardiogram results as the gold standard; these results indicate its utility as a decision support tool, though it is not intended as a standalone diagnostic method.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific features or types of murmurs does the AI algorithm identify beyond a general 'abnormal' classification, and does it differentiate between systolic and diastolic murmurs?; How does the proprietary echocardiogram-validated database used for training the AI account for variability in patient demographics (age, sex, BMI), comorbidities, and stethoscope placement techniques by different users?; What were the specific acoustic criteria and clinical definitions used to classify 'benign murmurs' as 'normal' by the AusculThing ACC algorithm?; How does the system's performance (sensitivity, specificity, accuracy) specifically vary between adult and pediatric populations, particularly in distinguishing innocent pediatric murmurs from pathological ones, given the combined validation data?; What safeguards or real-time feedback mechanisms are integrated into the mobile app to ensure optimal heart sound recording quality by healthcare providers with varying levels of auscultation expertise?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.