Medscape Medical NewsAll articles

SwiftMR

AIRS Medical Inc. • Radiology • 10/27/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

SwiftMR is a software solution that utilizes a deep learning-based convolutional neural network and an additional sharpening filter to automatically enhance MR images by reducing noise and increasing sharpness across all body parts and various acquisition parameters. The system aims to improve image quality for clinical review by processing DICOM images from PACS or MRI scanners and returning the enhanced images, with validated performance in improving Signal-to-Noise Ratio and image sharpness.

Summary

SwiftMR is a stand-alone software solution designed to enhance Magnetic Resonance (MR) images in DICOM format from all body parts. Its primary purpose is to improve image quality by reducing noise and increasing sharpness, thereby aiding radiology technologists in imaging centers, clinics, or hospitals. The system operates by receiving MR DICOM images from Picture Archiving and Communication Systems (PACS) or directly from MRI scanners. It then employs a deep learning algorithm, specifically a convolutional neural network (CNN)-based filter, which performs both noise reduction (with adjustable denoising levels from 0 to 8) and initial sharpening. An additional sharpening filter (with adjustable sharpness levels from 0 to 5) can be applied to further refine the image. The processed, enhanced images are then transferred back to PACS or the MR device in DICOM format. The SwiftMR software integrates into existing workflows, operating automatically in the background to process images from various MRI scanners with field strengths ranging from 0.25T to 3.0T, supporting a wide array of protocols (T1, T2, T2*, FLAIR, PD, DWI, MRA). A single deep learning model is utilized for all image types and body parts, including neuro, musculoskeletal, cardiac, and general body regions. The system allows users to monitor processing status and provides administrative controls for system settings, alongside functions for image processing, quality check, and progress monitoring. Validation testing demonstrated successful performance: noise reduction met criteria by increasing Signal-to-Noise Ratio (SNR) by at least 40% (at level 1, with an incremental 1% increase per level) for over 90% of test images. Sharpness enhancement was also validated, showing a decrease in Full Width at Half Maximum (FWHM) by specified percentages (ranging from 0.13% for the deep learning model alone up to 4.5% for filter level 5) for over 90% of the dataset, which included diverse patient demographics, anatomical regions, and MR manufacturers, and images with up to 50% scan time reduction.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

SwiftMRMRI EnhancementDeep LearningNoise ReductionImage SharpeningDICOMConvolutional Neural NetworkPACS IntegrationMedical Image ProcessingStand-alone Software

Device Metadata

Submission Number
K230854
Company
AIRS Medical Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the single deep learning model adapt its noise reduction and sharpening capabilities across different MRI field strengths (0.25T to 3.0T) and diverse anatomical regions without compromising performance?; What are the specific quantitative differences in image quality improvement (e.g., SNR, CNR, edge sharpness) when the deep learning model performs sharpening versus when only the additional sharpening filter is applied, or both are used in conjunction?; Given its ability to handle images with up to 50% scan time reduction, what is the impact of SwiftMR processing on diagnostic accuracy or the visibility of subtle pathologies in these accelerated acquisition scenarios?; How does the system ensure robustness and consistent performance when encountering MR images with artifacts or unusual acquisition parameters not extensively covered in the training/validation datasets?; What mechanisms are in place within the "quality check" function to flag or alert users if the enhancement process potentially introduces artifacts or obscures diagnostically relevant information?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
SwiftMR - AIRS Medical Inc. | ESL FDA AI Device Intelligence