Medscape Medical NewsAll articles

SIS System

Surgical Information Sciences, Inc. • Radiology • 05/02/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The SIS System is an advanced software platform employing machine learning and image processing, including deep learning neural networks trained on high-resolution 7T MRI data, to generate patient-specific 3D models of deep brain structures like the STN and GPi/GPe from standard clinical MR images. Its purpose is to enhance visualization and localization for neurological procedures such as Deep Brain Stimulation, integrating pre-operative planning with post-operative assessment by identifying implanted leads on CT scans relative to the modeled anatomy.

Summary

The SIS System by Surgical Information Sciences is a software-based medical image management and processing system designed for viewing, presenting, and documenting medical imaging. Its core functionality involves advanced image processing, image fusion, and intraoperative functional planning, providing 3D outputs compatible with stereotactic image-guided surgery systems. The system utilizes machine learning, specifically pre-trained deep learning neural networks, to enhance standard clinical MR images and generate patient-specific 3D anatomical models of critical brain structures such as the subthalamic nuclei (STN) and globus pallidus (GPe/GPi). This aids clinicians, including surgeons, neurologists, and radiologists, in visualizing and locating these structures for neurological procedures, particularly for planning Deep Brain Stimulation (DBS) lead placement, by supplementing standard clinical methods. This version of the SIS System builds upon a prior iteration (K223032) with key modifications: the addition of two compatible leads, minor adjustments to the image registration algorithm, and a new feature allowing users to view post-operative 3D models in different coordinate systems. Comprehensive software verification and validation were conducted, including repeated tests for visualization accuracy of STN and GPi/GPe, MRI to CT registration, CT image processing for lead segmentation, electrode orientation for new and existing leads, and extended validation of the head pose for standardized views. The performance data confirmed that the updated SIS System is fully verified and validated, functions as intended, and maintains its safety and effectiveness for aiding in the visualization of brain structures and planning stereotactic surgical procedures.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

SIS SystemMedical Imaging SoftwareImage ProcessingMachine LearningDeep Brain Stimulation (DBS)Neurological ProceduresSubthalamic Nucleus (STN)Globus Pallidus (GPi/GPe)Stereotactic Surgical Planning3D Anatomical Modeling

Device Metadata

Submission Number
K230977
Company
Surgical Information Sciences, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the system's performance in visualizing STN and GPi/GPe, particularly the segmentation accuracy, vary with different MRI sequence parameters or across images from MRI scanners of different field strengths (e.g., 1.5T vs 3T clinical scanners)?; What are the specific metrics used to validate the 'minor modification' to the image registration algorithm, and what was the quantitative improvement, if any, in MRI-CT registration accuracy?; Given the deep learning models are pre-trained using 7T MRI data for ground truth, what is the process or feasibility for site-specific adaptation or validation if discrepancies are noted with local clinical imaging protocols or patient populations?; For the two newly added compatible leads, what were the key challenges in validating their segmentation and electrode orientation, and how does their performance compare to previously supported leads?; How does the feature allowing users to view the post-operative 3D model in a different coordinate system enhance clinical utility or integrate with existing neuronavigation workflows beyond the standardized head position view?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, deep learning, neural network, algorithm, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.