Medscape Medical NewsAll articles

EFAI NeuroSuite CT ICH Assessment System

Ever Fortune.AI Co., Ltd. • Radiology • 10/04/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EFAI NeuroSuite CT ICH Assessment System is a software tool that employs deep learning algorithms to analyze adult non-contrast head CT scans for features suggestive of acute intracranial hemorrhage, thereby facilitating expedited clinical review through worklist prioritization. Its core science involves automated image feature extraction and classification, with its methodology validated by demonstrating high sensitivity and specificity in a multisite clinical study for identifying potential ICH cases.

Summary

The EFAI NeuroSuite CT ICH Assessment System (EFAI ICHCT) is an advanced software tool designed to assist in the radiological workflow by prioritizing adult non-contrast head CT scans suspected of containing acute intracranial hemorrhage (ICH). Utilizing deep learning algorithms, the system automatically analyzes CT images to detect features suggestive of ICH and subsequently sends case-level notifications to PACS or workstations, facilitating earlier review of potentially critical cases. The development of its AI model was based on a retrospective analysis of 5,365 adult head CT studies from Taiwan. EFAI ICHCT functions as a triage aid, providing passive notifications for worklist prioritization without highlighting specific image regions or serving as a standalone diagnostic tool. The system's efficacy was established through a retrospective, blinded, multisite clinical validation study involving 288 adult non-contrast head CT scans from 23 U.S. clinical sites, distinct from the training dataset, with ground truth determined by consensus from three board-certified neuroradiologists. This validation demonstrated high performance, achieving a sensitivity of 0.947, a specificity of 0.949, and an AUROC of 0.983 for ICH detection, with an average processing time of approximately 35 seconds per scan. Consistent performance was observed across various subgroups, including different patient demographics, CT scanner types, and ICH characteristics, underscoring its potential to reliably aid in the triage process.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Intracranial HemorrhageDeep LearningCT ScanTriageRadiologyWorkflow PrioritizationNon-contrast Head CTClinical ValidationSensitivitySpecificity

Device Metadata

Submission Number
K231025
Company
Ever Fortune.AI Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the EFAI ICHCT algorithm's performance vary with different subtypes and anatomical locations of intracranial hemorrhage (e.g., subdural, epidural, subarachnoid, intraparenchymal)?; What impact does the image quality (e.g., noise, artifacts, slice thickness variations beyond the tested subgroup ranges) have on the deep learning model's accuracy and reliability in detecting ICH?; Beyond the reported sensitivity and specificity, what is the positive predictive value (PPV) and negative predictive value (NPV) in a real-world clinical setting with varying ICH prevalence rates?; How does the EFAI ICHCT system integrate with different existing PACS/RIS environments, and what are the technical requirements for its implementation?; Were there any specific characteristics of the 5,365 cases used for model development (e.g., specific ICH types, patient comorbidities) that might influence its generalizability to populations significantly different from the Taiwanese cohort used for initial training?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EFAI NeuroSuite CT ICH Assessment System - Ever Fortune.AI Co., Ltd. | ESL FDA AI Device Intelligence