Medscape Medical NewsAll articles

qXR-CTR

Qure.ai Technologies • Radiology • 09/22/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The qXR-CTR device employs a deep-learning artificial intelligence algorithm to automatically analyze posterior-anterior chest X-rays, providing quantitative measurements of cardiac and thoracic diameters for calculating the cardiothoracic ratio. Its purpose is to assist physicians by offering an accurate and automated assessment tool for adult patients, enhancing radiological image processing without replacing clinical judgment.

Summary

qXR-CTR, developed by Qure.ai Technologies, is a deep-learning based software designed for the automated assessment of the cardiothoracic ratio (CTR) on posterior-anterior (PA) view chest X-ray (CXR) scans. Utilizing an artificial intelligence algorithm, it analyzes DICOM images to measure the maximal transverse diameter of the heart (CD) and the maximal inner transverse diameter (TD) of the thoracic cavity, subsequently calculating the CTR value. The system is intended for use by physicians or licensed practitioners in healthcare institutions like clinics and hospitals to aid in the assessment of adult patients (≥ 22 years of age), providing a structured report with a preview of the CXR, annotation lines for CD and TD, and the derived CTR, but is not meant for standalone clinical decision-making. The clinical performance of qXR-CTR was validated using 435 CXR scans from the US, with ground truth established by three experienced ABR thoracic radiologists. The software demonstrated accuracy with Root Mean Squared Error (RMSE) values of 7.55 mm for cardiac diameter, 5.43 mm for thoracic diameter, and 0.03 for the CTR. The Mean Absolute Error (MAE) for cardiac diameter was 5.66 mm (standard deviation 5.0 mm), and for thoracic diameter, it was 4.04 mm (standard deviation 3.63 mm), with an MAE for CTR of 0.02 (standard deviation 0.02). These results indicate the device's capability to provide reliable automated measurements to assist clinicians.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Cardiothoracic RatioChest X-rayDeep LearningArtificial IntelligenceMedical Image AnalysisDICOMCardiac DiameterThoracic DiameterAutomated AssessmentRadiological Software

Device Metadata

Submission Number
K231149
Company
Qure.ai Technologies
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the qXR-CTR algorithm's performance vary across different patient demographics (e.g., age, sex, BMI) and varying image qualities?; What specific deep learning architecture is employed in qXR-CTR, and how was it trained and validated to ensure robustness against common CXR artifacts or unusual anatomies?; Beyond RMSE and MAE, what other performance metrics (e.g., sensitivity/specificity for detecting cardiomegaly, inter-observer variability compared to manual measurements) were evaluated or could be relevant for clinical utility?; How does the device handle edge cases, such as images with significant pleural effusion, lung opacities, or anatomical variants that might obscure cardiac or thoracic borders?; What is the processing time per image, and how does the software integrate into existing hospital Picture Archiving and Communication Systems (PACS) and radiology workflows?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, ground truth, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
qXR-CTR - Qure.ai Technologies | ESL FDA AI Device Intelligence