Medscape Medical NewsAll articles

syngo.CT Lung CAD (Version VD30)

Siemens Healthcare GmbH • Radiology • 07/19/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

syngo.CT Lung CAD (Version VD30) is an advanced computer-aided detection tool that utilizes Convolutional Neural Networks to assist radiologists in the identification of solid and subsolid pulmonary nodules within MDCT chest scans. The system's methodology features enhanced lung segmentation, nodule classification, and a novel 'solid-only' operational mode with improved post-filtering, aiming to increase detection sensitivity while significantly reducing false positives for more efficient radiological review.

Summary

syngo.CT Lung CAD (Version VD30) is a software tool designed to aid radiologists in detecting solid and subsolid pulmonary nodules from multi-detector computed tomography (MDCT) chest examinations. Functioning as an adjunctive aid, it processes images to highlight potential regions of interest (ROIs) that might otherwise be missed, supporting nodule detection for solid types (3.0mm to 30.0mm) and subsolid types (5.0mm to 30.0mm). The system can be integrated into workflows as either a concurrent first reader or a second reader and sends its findings to a separate visualization application for display. A key update in Version VD30 is the introduction of a "solid-only" mode, which filters out suspected sub-solid and fully calcified CAD findings, allowing for a more focused review when desired. The underlying science of syngo.CT Lung CAD VD30 relies on Convolutional Neural Networks (CNNs) for its image analysis pipeline, which includes several stages: preprocessing involving isotropic volume resampling and advanced lung segmentation that now classifies at the lobe level; candidate generation using CNNs to identify potential nodules from image subvolumes; candidate classification also employing CNNs to determine the likelihood of a candidate being a true nodule; and an enhanced post-filtering process. This post-filtering in VD30 uses three cascaded filters, with the third new filter assigning nodule type labels (solid, non-solid, fully calcified) and enabling the "solid-only" mode. Performance evaluations using 712 CT cases indicated that VD30's "solid-only" mode achieved non-inferior sensitivity to the previous version's standard mode but with significantly fewer false positives, and overall, VD30 demonstrated improved accuracy.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary NodulesComputer-Aided Detection (CAD)Computed Tomography (CT)Convolutional Neural Networks (CNN)Image ProcessingLung SegmentationRadiology SoftwareSolid NodulesSubsolid NodulesFalse Positive Reduction

Device Metadata

Submission Number
K231157
Company
Siemens Healthcare GmbH
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the performance of the 'solid-only' mode in syngo.CT Lung CAD VD30 compare to its standard mode specifically for the detection of purely solid nodules, in terms of both sensitivity and false positive reduction?; What is the quantitative impact of the new lobe-level lung segmentation in VD30 on the accuracy of nodule detection, especially for nodules located near interlobar fissures or in complex anatomical regions?; What is the validated accuracy of the third post-filtering step in VD30 for classifying nodules into solid, non-solid, and fully calcified types, and how might misclassification impact clinical interpretation?; Considering the syngo.CT Lung CAD VD30 algorithm operates without its own user interface, what are the specified performance and integration requirements for hosting applications to ensure the CAD marks and findings are displayed optimally and without introducing interpretation errors?; How does the CNN-based algorithm in syngo.CT Lung CAD VD30 maintain its performance across CT scanners from different vendors and varying acquisition protocols (e.g., dose levels, reconstruction kernels) not explicitly covered in the provided validation data?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(neural network, algorithm, preprocessing)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
syngo.CT Lung CAD (Version VD30) - Siemens Healthcare GmbH | ESL FDA AI Device Intelligence