Device Purpose
The EPIQ Series Diagnostic Ultrasound System has been enhanced with the mL26-8 linear array transducer, expanding its capabilities to high-resolution superficial and Ophthalmic imaging. This advancement relies on established ultrasound principles and rigorous non-clinical testing to ensure its safety and effectiveness for diverse diagnostic applications.
Summary
The EPIQ Series Diagnostic Ultrasound System has been updated to incorporate the new mL26-8 transducer, a linear array probe operating at a frequency of 6-13.33 MHz. This transducer is specifically designed for high-resolution superficial imaging, targeting applications such as Musculoskeletal (Superficial), Ophthalmic, Pediatric, Peripheral Vessel, and Small Organ imaging (including Breast, Thyroid, and Testicle). A key enhancement with this update is the expansion of the system's indications for use to include Ophthalmic applications, a capability supported by data from a reference device. The system functions through diagnostic ultrasound imaging and fluid flow analysis, employing technologies like pulsed Doppler and pulsed echo imaging. The introduction of the mL26-8 transducer, with its higher frequency range (within established guidance limits), aims to improve image quality for superficial structures. The safety and effectiveness of the system, including the new transducer, were validated through comprehensive non-clinical performance testing. This testing encompassed adherence to various industry standards for medical electrical equipment, electromagnetic compatibility, usability, and specific requirements for ultrasonic diagnostic equipment, ensuring the device meets its design specifications and risk control measures without requiring new clinical trials for this particular update.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific advantages does the 6-13.33 MHz frequency range of the mL26-8 transducer offer for Ophthalmic and superficial musculoskeletal imaging compared to existing transducers in the EPIQ series?; How does the image quality and diagnostic yield of the mL26-8 transducer compare to other high-frequency linear transducers in similar applications, particularly in differentiating subtle tissue abnormalities in small organs or peripheral vessels?; Were any specific phantom studies or bench tests conducted to validate the performance of the mL26-8 transducer for its newly expanded Ophthalmic indication, and what were the key performance metrics assessed?; Given the integration capability with Philips EchoNavigator for cardiovascular procedures, are there any specific enhancements or considerations when using the mL26-8 transducer in conjunction with this image guidance system?; What are the documented improvements in spatial and contrast resolution with the mL26-8 transducer for its intended superficial applications, and how does this translate to enhanced diagnostic confidence for clinicians?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly