Brainomix 360 Triage ICH

Brainomix Limited • Radiology • 07/27/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Brainomix 360 Triage ICH is an AI-driven software that analyzes adult non-contrast CT brain scans to detect hyperdense volumes indicative of intracranial hemorrhage, providing rapid notifications to specialists for workflow prioritization in acute settings. Its methodology relies on machine learning algorithms for image analysis operating in parallel to standard care, intended for triage assistance rather than standalone diagnosis, with specific performance characteristics and usage limitations.

Summary

Brainomix 360 Triage ICH is a radiological computer-aided triage and notification software designed to assist clinicians in rapidly identifying suspected intracranial hemorrhage (ICH) in adult patients. The system utilizes an artificial intelligence algorithm to analyze non-contrast CT (NCCT) images of the brain acquired within 24 hours of acute symptom onset or last known well time. Its primary function is to provide a notification-only, parallel workflow tool, sending alerts to neurovascular or neurosurgical specialists about potential ICH cases, thereby facilitating prioritization for image review. The device allows for image preview via a mobile application or a web user interface, emphasizing that these compressed images are for informational purposes only and not for diagnostic use beyond notification; clinicians must review non-compressed images on a diagnostic viewer for actual diagnostic decisions. The software is specifically optimized to detect hyperdense volumes in the parenchyma associated with acute ICH but is not intended to detect isolated subarachnoid hemorrhage and has limitations regarding scanner compatibility (validated on GE and Philips scanners) and specific patient conditions like recent neurosurgery or certain intracranial pathologies. A retrospective study involving 341 NCCT scans was conducted to evaluate the standalone performance of the Triage ICH image analysis algorithm against a ground truth established by experienced neuroradiologists. The study demonstrated an overall sensitivity of 89.22% and a specificity of 91.37% in detecting ICH, meeting pre-specified performance goals. Performance was further stratified by ICH subtype, showing varied sensitivity (e.g., 96.61% for Intraparenchymal Hemorrhage, 35.71% for Subarachnoid Hemorrhage). The time to notification for the Triage ICH device ranged from 50 to 126 seconds, reported as substantially lower than the average time to notification for the standard of care in the predicate device. The system processes DICOM standard images on an off-the-shelf server and integrates into the Brainomix 360 Platform, using machine learning for automated ICH detection but does not alter original images or replace full patient evaluation for diagnosis.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Intracranial Hemorrhage (ICH)Artificial IntelligenceTriage SoftwareNon-Contrast CT (NCCT)Notification SystemMachine LearningRadiological ImagingHyperdense VolumeSensitivitySpecificity

Device Metadata

Submission Number
K231195
Company
Brainomix Limited
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the algorithm's performance, particularly the reported sensitivity for Subarachnoid Hemorrhage (35.71%) and Subdural Hemorrhage (66.67%), impact its clinical utility for comprehensive ICH triage, especially considering the device is not intended to detect isolated SAH?; What specific features of the machine learning algorithm allow it to differentiate hyperdense volumes of acute intracranial hemorrhage from other hyperdensities, such as calcifications or contrast, if a patient inadvertently had a contrast CT?; Given the device is validated on GE and Philips scanners, what is the anticipated performance variability or potential for failure if used with NCCT images from other manufacturers or with significantly different acquisition protocols (e.g., varying slice thickness beyond the tested ranges)?; How does the pre-processing and registration involving image rotation and resampling for the web UI's 'straightened images' potentially affect the visual interpretation of subtle ICH findings compared to the original DICOM images, even for preview purposes?; What are the quantitative differences in algorithm performance when stratifying by the source of scans (Boston Medical Centre vs. 'Other' referral hospitals), and what might account for these differences beyond patient demographics?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Brainomix 360 Triage ICH - Brainomix Limited | ESL FDA AI Device Intelligence