Medscape Medical NewsAll articles

Cleerly ISCHEMIA

Cleerly, Inc • Cardiovascular • 09/08/2023

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

Cleerly ISCHEMIA is a machine learning-based software designed as an adjunctive diagnostic tool to non-invasively assess the likelihood of coronary ischemia. It analyzes quantitative CCTA data, including atherosclerosis and stenosis metrics, to provide a binary ischemia index benchmarked against invasive FFR, aiming to support clinical decision-making for patients with suspected coronary artery disease.

Summary

Cleerly ISCHEMIA is an automated, machine learning-based decision support software designed to aid in the diagnosis of ischemia associated with coronary artery disease (CAD). Functioning as an add-on module to Cleerly Labs, it analyzes Coronary Computed Tomography Angiography (CCTA) images to quantify atherosclerosis, stenosis, and vascular morphology, thereby determining the likely presence or absence of coronary vessel ischemia. The software employs a "locked" algorithm, meaning it does not continuously learn, and processes eligible vessel data through pre-processing and post-processing modules. Its output, the Cleerly ISCHEMIA Index (CII), is a binary indicator (positive/negative for likely ischemia) benchmarked against an invasive Fractional Flow Reserve (FFR) threshold of ≤0.80, and results are visually displayed, with vessels indicating likely ischemia illuminated in red, to non-invasively support the functional evaluation of stable symptomatic CAD patients. The clinical performance of Cleerly ISCHEMIA was validated primarily through the CREDENCE trial, a prospective, multicenter study involving 612 stable patients with suspected CAD, using invasive FFR as the reference standard. In this trial, the software demonstrated a per-vessel territory sensitivity of 75.9% and a specificity of 83.4% for its primary endpoint. Further performance data, including pooled results from US and international studies, showed combined per-vessel sensitivity and specificity of 76.2% and 85.2% respectively, with a negative predictive value (NPV) of 90.5%. On a per-patient basis, the pooled data indicated a sensitivity of 86.6% and a specificity of 69.8%, with an NPV of 84.6%. Non-clinical testing also verified the software's risk assessment, performance, and cybersecurity.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Cleerly ISCHEMIAIschemiaCoronary Artery DiseaseCCTAMachine LearningDecision Support ToolFractional Flow ReserveAtherosclerosisStenosisDiagnostic Aid

Device Metadata

Submission Number
K231335
Company
Cleerly, Inc
Panel
Cardiovascular
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the 'locked' nature of the Cleerly ISCHEMIA algorithm affect its adaptability to evolving CCTA imaging technologies or new understandings of ischemia predictors over time?; What specific quantitative measures of atherosclerosis, stenosis, and vascular morphology are weighted most heavily by the algorithm in determining the Cleerly ISCHEMIA Index, and are these weightings transparent to the user?; Given the difference in specificity between per-vessel (85.2% pooled) and per-patient (69.8% pooled) analyses, what are the clinical implications for potential over- or under-treatment based on the unit of analysis?; What were the exclusion criteria for vessels or studies in the pre-processing module, and how might these exclusions impact the generalizability of the tool in a diverse patient population with complex coronary anatomy?; How does the performance of Cleerly ISCHEMIA compare to other non-invasive ischemia assessment modalities, such as stress echocardiography or SPECT MPI, particularly in subgroups of patients defined by disease severity or comorbidities?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Cleerly ISCHEMIA - Cleerly, Inc | ESL FDA AI Device Intelligence