CEPHX- Cephalometric Analysis Software
Orca Dental AI LTD • Radiology • 01/31/2024
Device Purpose
CEPHX - Cephalometric Analysis Software utilizes artificial intelligence to automatically detect 99 landmarks on 2D cephalometric x-ray images, providing dentists with a tool for orthodontic image analysis, diagnosis, and treatment planning simulation. The system aims to enhance clinical workflow by offering automated landmarking and analytical reports, with its performance validated by achieving 99% accuracy in landmark identification within a 2.0mm margin compared to specialist orthodontists.
Summary
CEPHX - Cephalometric Analysis Software is a medical imaging software designed to assist dentists providing orthodontic treatment. Its primary purpose is to facilitate image analysis, treatment simulation, profilogram creation, Visual Treatment Objective (VTO) generation, and patient consultation. The software operates by processing 2D cephalometric x-ray images uploaded by the user. Utilizing artificial intelligence, it automatically generates 99 cephalometric landmark points on these images. These landmarks, which are crucial points on a lateral radiographic view of the teeth, jaws, and skull base, form the basis for various cephalometric analyses, aiding in the diagnosis of facial abnormalities and planning orthodontic interventions. Dentists can then generate comprehensive reports using a selection of built-in analysis methods or by creating custom analyses through an "Analysis Wizard." The software is intended for use by qualified and trained dentists as a supportive tool; the diagnostic and treatment planning results derived from it are explicitly dependent on the professional interpretation of these licensed practitioners. It is indicated for patients aged 14 years and older. Performance data from a verification study demonstrated the software's accuracy in landmark detection. In this study, AI-generated landmarks were compared against those manually identified by three orthodontic specialists. The results showed that 99% of 21 clinically significant landmarks were identified by the AI within a 2.0mm "pass" margin compared to the specialists' consensus, meeting predefined accuracy endpoints and supporting its reliability for clinical support.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific AI algorithms or machine learning models are employed for the automated detection of the 99 cephalometric landmarks, and how were these models trained and validated beyond the described study?; How does the software's performance vary across different qualities of cephalometric images (e.g., images with noise, artifacts, or poor contrast) or in patients with significant craniofacial anomalies?; The study mentions 21 clinically significant landmarks were compared with a 2.0mm "pass" margin. How were these 21 landmarks selected from the 99 generated, and what is the clinical significance of the 2.0mm threshold for orthodontic decision-making?; Beyond landmark identification, what is the extent and accuracy of the "simulation" and "Visual Treatment Objective (VTO)" features, and how do these compare to manual prediction methods or other VTO software?; Given the software is a supporting tool, what guidance or training is provided to dentists to ensure they correctly interpret the AI-generated landmarks and subsequent analyses, especially in cases where the AI might deviate from typical presentations?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.