MAGNETOM Cima.X
Siemens Medical Solutions USA, Inc. • Radiology • 12/18/2023
Device Purpose
The MAGNETOM Cima.X is an advanced magnetic resonance diagnostic device designed to enhance diagnostic imaging of the head, body, and extremities through upgraded hardware, including a new 3D camera and modified gradient coil. It employs syngo MR XA61A software featuring novel AI-driven image reconstruction techniques like Deep Resolve Boost and new pulse sequences such as MR Fingerprinting, aiming to improve image quality and diagnostic capabilities as validated by nonclinical testing and supported by existing clinical literature.
Summary
The MAGNETOM Cima.X, operating with syngo MR XA61A software, is a magnetic resonance diagnostic device designed to generate cross-sectional images (transverse, sagittal, coronal, oblique), spectroscopic images, and spectra of the head, body, or extremities. Its purpose is to display internal structures and functions, potentially deriving other physical parameters to aid physicians in diagnosis, with the option of using contrast agents and supporting imaging during MR-compatible interventional procedures; the system incorporates new hardware components like a 3D camera, and modified elements including host computers, gradient coil, and body coil, alongside a suite of new and enhanced software features. Key software advancements in the MAGNETOM Cima.X include new applications such as Deep Resolve Boost (for HASTE and EPI Diffusion), Open Recon, Ghost reduction (DPG), and SAMER, alongside the integration of MR Fingerprinting, with Deep Resolve features leveraging artificial intelligence trained on extensive datasets (tens of thousands to over a million slices) covering diverse body parts and imaging conditions, using metrics like PSNR and SSIM for validation; while no new clinical trials were conducted, the system's performance and safety were evaluated through nonclinical testing, including software verification, image quality assessments with sample clinical images, hardware bench tests, and adherence to international safety and EMC standards, supported by existing clinical publications for specific features.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of "Deep Resolve Boost EPI Diffusion" on the MAGNETOM Cima.X compare to conventional EPI diffusion sequences in terms of quantitative metrics (e.g., ADC values, SNR, CNR) and diagnostic accuracy for specific pathologies, beyond the cited publications?; What is the specific impact of the new 3D camera on workflow efficiency and patient positioning accuracy, and are there quantitative data to support these improvements?; Can the "Open Recon" feature be customized by users to integrate their own reconstruction algorithms, and what are the computational requirements and compatibility considerations for such custom integrations?; Given that demographic data (age, gender, ethnicity) were not recorded for AI model training due to privacy concerns, what steps were taken to ensure the robustness and fairness of the "Deep Resolve" AI algorithms across diverse patient populations?; How do the modifications to the gradient coil in MAGNETOM Cima.X specifically contribute to improved image quality or acquisition speed for advanced applications like MR Fingerprinting, compared to the predicate device?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, HBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.