Spine CAMP (1.1)
Medical Metrics, Inc. • Radiology • 07/07/2023
Device Purpose
Spine CAMP™ (1.1) is an automated software system designed to analyze spinal X-rays using an AI-driven image processing methodology to provide quantitative metrics on spinal morphology, alignment, and motion. It aims to support clinical decision-making by objectively characterizing spinal health, including intervertebral motion and spinopelvic parameters, with performance demonstrated through statistical equivalence to predicate and reference methods.
Summary
Spine CAMP™ (1.1) is a fully-automated image processing software designed to assist healthcare professionals in assessing spinal health. It analyzes sagittal plane X-ray images of the lumbar and/or cervical spine from skeletally mature patients (18 years and older). The software aims to provide objective metrics for characterizing spinal conditions such as stability, alignment, degeneration, fusion, motion preservation, and implant performance, thereby supporting clinical decision-making. The system employs an artificial intelligence (AI) engine for vertebral body detection, landmark specification, and registration. It calculates various measurements including distances, angles, linear and angular displacements, and presents these findings in reports, annotated images, and visualizations of intervertebral motion using an image registration method called "stabilization." Version 1.1 features an AI engine retrained with additional imaging data for enhanced performance and generalization, includes logic improvements, and introduces the capability to identify femoral heads for spinopelvic measurements. Performance testing, including comparisons against its previous version (v1.0) and a reference method (QMA) for spinopelvic parameters on a dataset of over 400 radiographs, demonstrated statistical equivalence in vertebral landmark coordinates, image calibration, and intervertebral and spinopelvic measurements.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the "stabilization" image registration method account for patient positioning variability between flexion/extension X-rays when assessing intervertebral motion?; What specific AI models are used within the AI Engine, and what was the diversity of the "more imaging" dataset used for retraining in terms of patient demographics, pathologies, and image quality?; How does the software's performance in identifying femoral heads and generating spinopelvic measurements compare to manual measurements by expert radiologists in terms of accuracy and inter-observer variability?; What are the known failure modes of the AI Engine, even after logic improvements, and what are the recommended actions for users when the software fails to provide an accurate analysis?; Beyond statistical equivalence, what is the clinical impact of using Spine CAMP™ v1.1 on diagnostic accuracy, treatment planning efficiency, or patient outcomes compared to traditional assessment methods?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly