Medscape Medical NewsAll articles

EdgeFlow UH10

Edgecare Inc. • Radiology • 03/06/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EdgeFlow UH10 is a portable ultrasound device that employs a deep learning model for the noninvasive measurement of bladder urine volume. Its methodology relies on AI-driven B-mode ultrasound image classification for bladder detection and semantic segmentation for boundary delineation, with clinical validation demonstrating high accuracy through F1 and Dice scores.

Summary

The EdgeFlow UH10 is a portable ultrasound system designed for noninvasive measurement of urine volume in the bladder. It comprises a handheld console with a 3.2-inch touchscreen display and an integrated probe, utilizing B-mode and harmonic imaging modes. The core of its operation is a deep learning model which includes feature extraction, a binary classification network to determine bladder presence, and a semantic segmentation network to delineate the bladder area from ultrasound images. The system calculates bladder volume based on these AI-generated contours, displays the images and volume, and allows for data export via USB or Wi-Fi. It is powered by a rechargeable lithium-ion battery. The performance of the EdgeFlow UH10's deep learning model was validated using clinical data collected under an Institutional Review Board-approved trial, with distinct datasets for training and testing. For the classification network, tested on 3,711 images from 90 subjects, the device achieved an F1 score of 0.979 (95% CI 0.974–0.984), exceeding the predefined success criterion of ≥0.90, and also met its secondary endpoint criterion for Precision-Recall Area Under Curve (PR AUC) of ≥0.95. The segmentation network, evaluated using 1,528 images, achieved a Dice Score of 0.896 (95% CI 0.890–0.901), meeting its performance criterion of ≥0.89. These results demonstrate the system's accuracy for its intended use by qualified healthcare professionals in professional healthcare facilities.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

UltrasoundBladder VolumeNoninvasive MeasurementDeep LearningSemantic SegmentationImage ClassificationF1 ScoreDice ScorePortable Medical DeviceUrine Volume

Device Metadata

Submission Number
K231677
Company
Edgecare Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the EdgeFlow UH10's deep learning model account for anatomical variability in bladder shape across different patient demographics (e.g., age, sex, BMI) beyond the collected auxiliary demographic references?; What specific features are extracted by the 'feature extraction' component of the deep learning model, and how critical are they for the subsequent classification and segmentation tasks?; The document states the Precision-Recall Area Under Curve (PR AUC) criterion for the classification network was ≥0.95 and was met; what was the exact achieved PR AUC value, and how does it compare to the F1 score in reflecting performance on imbalanced datasets?; What were the inter-rater reliability metrics for the two evaluators who established the ground truths for the test dataset, and how were discrepancies in their reviews resolved?; How does the device's measurement accuracy of ±7.5mL for 0-100mL and ±7.5% for 100-999mL specifically perform at the extreme ends of these ranges, particularly for very low or very high bladder volumes?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, ground truth, feature extraction)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EdgeFlow UH10 - Edgecare Inc. | ESL FDA AI Device Intelligence