Cartesion Prime (PCD-1000A/3) V10.15
Canon Medical Systems Corporation • Radiology • 09/12/2023
Device Purpose
The Cartesion Prime (PCD-1000A/3) V10.15 is a hybrid PET/CT imaging system designed to provide comprehensive diagnostic information by imaging radiopharmaceutical distribution for metabolic and functional assessment, and X-ray transmission for anatomical detail. It enhances PET image quality through AiCE-i deep learning reconstruction for FDG data and incorporates a Deviceless PET Respiratory-gating system to mitigate motion artifacts by generating gating signals directly from PET data.
Summary
The Cartesion Prime (PCD-1000A/3) V10.15 is a diagnostic imaging system that integrates Positron Emission Tomography (PET) and X-ray Computed Tomography (CT) functionalities. The PET component visualizes the distribution of administered radiopharmaceuticals to gather metabolic and functional information for assessing physiologic functions, while the CT component provides cross-sectional anatomical images used for attenuation correction and anatomical reference in fused PET/CT images. This system is intended for use by trained healthcare professionals to aid in the evaluation, detection, localization, diagnosis, staging, restaging, follow-up, therapeutic planning, and therapeutic outcome assessment for a range of conditions, including oncological, cardiovascular, and neurological diseases. The device can also operate as a standalone whole-body multi-slice CT scanner. This version introduces two key technological advancements: AiCE-i for PET and a Deviceless PET Respiratory-gating system. AiCE-i for PET employs deep learning artificial neural network methods to enhance image quality and reduce noise in FDG whole-body PET data by analyzing the statistical properties of the signal and noise. The Deviceless PET Respiratory-gating system automatically generates a gating signal from list-mode PET data to reconstruct motion-corrected PET images, particularly beneficial for lesions in the thorax, abdomen, and pelvis affected by respiratory motion. Bench testing demonstrated that this deviceless system improves quantitative parameters like SUV accuracy and tumor volume compared to device-based gating. Clinical image review by experienced physicians confirmed that images acquired using the deviceless gating system were of diagnostic quality, performing as well as or better than non-gated or device-based gated images.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What is the quantifiable improvement in lesion detectability and standardized uptake value (SUV) accuracy when using the AiCE-i deep learning algorithm for PET, particularly for small or low-contrast lesions, compared to conventional reconstruction methods across various radiopharmaceuticals beyond FDG?; How does the Deviceless PET Respiratory-gating system algorithm differentiate between patient respiratory motion and other physiological movements, and what is its robustness across a spectrum of breathing patterns and patient conditions (e.g., arrhythmias, involuntary movements)?; What are the specific performance metrics (e.g., reduction in motion artifacts, improvement in spatial resolution) of the Deviceless PET Respiratory-gating system in imaging lesions in the thorax, abdomen, and pelvis, and how do these compare across different patient ages, body habitus, and disease types?; Are there any specific clinical scenarios or patient populations where the combination of AiCE-i and the Deviceless PET Respiratory-gating system demonstrates a synergistic effect on diagnostic accuracy or changes in therapeutic planning compared to using each technology independently?; What is the typical processing time added by the AiCE-i algorithm and the Deviceless PET Respiratory-gating system to the overall image reconstruction workflow, and how might this impact clinical throughput?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly