Medscape Medical NewsAll articles

BriefCase-Quantification

Aidoc Medical, Ltd. • Radiology • 11/13/2023

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

BriefCase-Quantification is an AI-powered software designed to automate the measurement of brain midline shift from non-contrast head CT images, aiding medical specialists by providing quantitative data and longitudinal tracking. Its methodology relies on a deep learning algorithm to process DICOM images and generate reports, with clinical studies demonstrating high accuracy (0.94 mm mean absolute error) and minimal bias compared to manual neuroradiologist assessments.

Summary

BriefCase-Quantification is an AI-driven radiological image management and processing software designed for the automatic measurement of brain midline shift (MLS) in non-contrast head CT (NCCT) images. It is intended for use in adults and transitional adolescents (18 years and older) to assist trained medical specialists by automating the traditionally manual MLS measurement process. The system operates on a cloud-based Linux server, processing filtered DICOM images using a deep learning algorithm. It can analyze images from a single time point or perform comparative analysis of images from the same individual acquired at multiple time points, without altering the original medical data. The output, delivered to PACS or a desktop application, includes a summary report with a preview image of the slice showing the largest MLS, annotations of the midline and septum pellucidum distance, and a table or graph for longitudinal MLS tracking. The software's performance was validated in a retrospective, multicenter, blinded study involving 284 NCCT cases from 228 unique patients, compared against a ground truth established by three neuroradiologists. The primary endpoint, the mean absolute error between the algorithm's measurement and the ground truth, was 0.94 mm (95% CI: 0.74 mm, 1.14 mm), meeting prespecified goals. A secondary endpoint, evaluated using a Bland-Altman plot, showed a mean difference of -0.15 mm, indicating minimal bias. For analyses of multiple time points for the same patient, the mean absolute error was 1.16 mm for initial scans and 1.28 mm for follow-up scans, also meeting performance goals. The device is intended as an assistive tool and not for stand-alone diagnostic decision-making; clinicians maintain responsibility for comprehensive image review.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Midline Shift (MLS)Non-Contrast Head CT (NCCT)Automatic MeasurementArtificial Intelligence (AI)Deep LearningImage Processing SoftwareDICOMNeuroradiologyQuantitative ImagingLongitudinal Analysis

Device Metadata

Submission Number
K232083
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the algorithm's performance vary across different CT scanner manufacturers and imaging protocols beyond those tested in the pivotal study?; What is the typical processing time for a single NCCT series, and how does this integrate into high-volume clinical workflows?; Are there specific anatomical variants or pathological conditions (e.g., severe skull fractures, post-craniotomy changes) that might affect the accuracy of the midline shift measurement?; How does the software handle cases with suboptimal image quality or significant motion artifacts?; What were the specific prespecified performance goals for the primary and secondary endpoints in the pivotal study, and how do they compare to clinically acceptable margins of error for MLS measurement?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, ground truth, bias, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase-Quantification - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence