Medscape Medical NewsAll articles

InVision Precision LVEF (LVEF)

InVision Medical Technology Corporation • Radiology • 04/25/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

InVision Precision LVEF is a software medical device that employs a machine learning algorithm with spatiotemporal pooling for semi-automated segmentation of the left ventricle from transthoracic echocardiograms to calculate Left Ventricular Ejection Fraction. The system aims to assist clinicians by providing adjustable, real-time LVEF estimations from DICOM images integrated within PACS, with its performance in estimating LVEF and segmentation accuracy validated by RMSD and Dice scores against cardiologist consensus.

Summary

The InVision Precision LVEF is a Software as a Medical Device (SaMD) designed to assist clinicians in cardiac evaluations by providing automated estimations of Left Ventricular Ejection Fraction (LVEF). It processes previously acquired transthoracic cardiac ultrasound images in DICOM format, allowing for image storage, manipulation, and measurement on various platforms including ultrasound devices, personal computers, or compatible DICOM-compliant PACS systems. Indicated for use in patients 22 years and older, the software is operated by sonographers and physicians to aid in the diagnostic review and analysis of echocardiographic data, particularly for LVEF assessment, by selecting appropriate echocardiogram videos and generating segmentations. The core of InVision Precision LVEF relies on a machine learning algorithm utilizing a spatiotemporal pooling network architecture to perform semi-automatic segmentation of the left ventricle from selected echocardiogram video views (single or biplane). This segmentation forms the basis for the LVEF calculation, which is presented as a numerical estimate with adjustable annotations that clinicians can modify, with the LVEF calculation updating in real-time. Performance was validated in a retrospective, multicenter study using data from various ultrasound equipment manufacturers, demonstrating an average Root Mean Square Deviation (RMSD) for biplane view LVEF of approximately 6.06 against ground truth, and Dice scores for A4C and A2C segmentations of 0.89 and 0.90 respectively, across diverse patient subgroups.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

LVEFEchocardiographyMachine LearningImage SegmentationDICOMPACSCardiac UltrasoundSemi-automatedSoftware as a Medical DeviceRMSD

Device Metadata

Submission Number
K232331
Company
InVision Medical Technology Corporation
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the 'spatiotemporal pooling' network architecture used by InVision Precision LVEF compare in performance and robustness to the 'simple pooling' used by the predicate device, particularly for challenging image qualities or rare cardiac conditions?; What specific training data characteristics (e.g., diversity of patient populations, range of LVEF values, image quality variations) were prioritized to ensure the generalizability and minimize bias in the machine learning model's LVEF estimations?; Given the semi-automated nature, what is the typical time saved or efficiency gained by clinicians using InVision Precision LVEF compared to manual LVEF calculation, and how frequently do users need to adjust the initial automated segmentations?; What are the performance metrics (RMSD, Dice score) for patient subgroups with particularly high or low LVEF values, or those with significant comorbidities that might affect cardiac image quality or morphology?; How does the system handle cases where the automated view selection algorithm fails to identify appropriate cardiac views, and what is the fallback mechanism for the user?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, algorithm, ground truth, model validation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
InVision Precision LVEF (LVEF) - InVision Medical Technology Corporation | ESL FDA AI Device Intelligence