Medscape Medical NewsAll articles

LungQ v3.0.0

Thirona BV • Radiology • 01/08/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

LungQ v3.0.0 is a software tool designed to provide quantitative analysis of pulmonary tissue from CT thoracic datasets, supporting physicians in diagnosis and follow-up. It employs automated 3D segmentation, volumetric and density analysis, and fissure evaluation to generate reproducible metrics from CT scans, with its performance validated through non-clinical testing including comparison to a predicate device and human expert assessments.

Summary

LungQ v3.0.0 is a software application designed to aid physicians by providing reproducible quantitative CT values for pulmonary tissue, thereby supporting the diagnosis and follow-up of pulmonary conditions using CT thoracic datasets. It functions as a command-line tool without a graphical user interface, processing DICOM images to perform automated three-dimensional segmentation of lungs, lobes, pulmonary sub-segments, and airways. The software offers capabilities for volumetric analysis, density evaluations (including 15th percentile density), fissure integrity assessment, and generates reports based on these analyses; user-initiated manual editing of segmentations is not supported. The underlying technology of LungQ v3.0.0 relies on computational algorithms to analyze CT scan data for quantitative measurements of lung structures. Its performance was evaluated through non-clinical testing, which included software verification, validation, and a head-to-head substantial equivalence study against its predicate, LungQ v1.1.0. This study compared key metrics such as lung and lobar volumes, density scores (LAA-950HU, LAA-910HU), 15th percentile lung density (PD15), and fissure completeness, using Bland-Altman plots and ROC analysis. The results indicated that LungQ v3.0.0 met predefined equivalence criteria, with differences from the predicate device falling within acceptable limits (e.g., volume differences ≤10%, fissure completeness Az value 0.97). Additionally, its (sub)segmental volume and density outputs showed good agreement with analyses corrected by human experts across various CT scanner models.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

LungQCT ScansPulmonary TissueQuantitative Analysis3D SegmentationVolumetric AnalysisDensity EvaluationFissure CompletenessThoracic ImagingCommand-line Software

Device Metadata

Submission Number
K232412
Company
Thirona BV
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does LungQ v3.0.0's algorithm for (sub)segmental segmentation compare in accuracy and robustness to other leading automated methods, particularly in cases with severe pathology or anatomical variations?; What is the specific impact of using a command-line interface without manual segmentation editing capabilities on clinical workflow efficiency and user adoption, especially for complex cases requiring adjustments?; Can the quantitative outputs of LungQ v3.0.0 (e.g., LAA-950HU, PD15) be reliably correlated with specific clinical outcomes or disease progression markers across diverse patient populations and CT acquisition protocols?; How sensitive is the fissure completeness evaluation to variations in CT slice thickness and reconstruction kernels, and what are the implications for its reliability in assessing collateral ventilation?; What are the performance characteristics of LungQ v3.0.0 when analyzing low-dose CT scans or scans with significant motion artifacts, and how does this affect the reproducibility of its quantitative measurements?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
LungQ v3.0.0 - Thirona BV | ESL FDA AI Device Intelligence