Innolitics, LLC • Radiology • 02/28/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

CT Cardiomegaly is a command-line software application that employs a non-adaptive machine learning algorithm to automatically analyze axial CT slices by segmenting the heart and thoracic cavity. Its primary function is to calculate both linear and area-based cardiothoracic ratios, providing quantitative data to assist clinicians in assessing cardiac size, with the explicit understanding that its results are not intended as a sole basis for diagnosis.

Summary

CT Cardiomegaly is a software-only medical device, functioning as a command-line application, designed to automatically calculate both linear and area-based cardiothoracic ratios (CTR) from computed tomography (CT) images that include the heart. It utilizes a non-adaptive machine learning algorithm, built using the MONAI framework, to identify and segment the heart and inner chest cavity from an axial CT slice. The software measures the maximal transverse diameter of the heart and the maximal inner transverse diameter of the thoracic cavity to derive these CTR values. Intended for use by physicians and licensed practitioners in various healthcare settings, it processes CT studies from adult and transitional adolescent patients (18-21 years old) and outputs results in PDF and JSON formats. These reports include the calculated ratios, patient information, and user-configurable reference values, but are not intended for standalone clinical decision-making. The machine learning algorithm within CT Cardiomegaly was trained using a reference standard derived from segmentations by three board-certified radiologists, with a training dataset of 1600 unique patient cases from 267 sites, ensuring no site overlap with the testing cohort which comprised 275 unique patient cases. This testing dataset was diverse, including varied patient demographics, confounding conditions, and imaging characteristics from numerous scanner manufacturers and protocols. Performance assessments demonstrated strong agreement with physician-derived measurements, achieving a mean difference of less than 0.01 for both Cardiothoracic Ratio (linear) and Heart to Chest Area Ratio (area-based). The 95% limits of agreement were reported as [-0.033, 0.035] for linear CTR and [-0.028, 0.035] for area-based CTR. Secondary endpoints, such as key heart slice detection accuracy (mean difference 0.46mm) and segmentation quality (Dice scores of 0.95 for heart and 0.98 for inner chest), further validated the device's analytical performance.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Cardiothoracic Ratio (CTR)Computed Tomography (CT)Machine LearningImage SegmentationAutomated MeasurementAxial CT SliceNon-adaptive AlgorithmLinear-based CTRArea-based CTRSoftware as a Medical Device (SaMD)

Device Metadata

Submission Number
K232613
Company
Innolitics, LLC
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the non-adaptive nature of the machine learning algorithm affect its performance on patient populations or imaging protocols significantly different from the training dataset of 1600 cases?; What specific image processing steps or algorithmic features are employed to reliably identify the optimal axial CT slice for CTR calculation from a full CT volume, especially in cases with anatomical variations or suboptimal image quality?; Given the device outputs both linear and area-based CTR, what is the comparative clinical sensitivity and specificity of area-based CTR versus linear-based CTR for detecting cardiomegaly when derived from CT images, and in what specific clinical scenarios might one be preferred over the other?; The performance data indicates strong agreement with human readers; however, what are the detailed characteristics of the 275 test cases, particularly regarding the prevalence and types of cardiomegaly or other co-existing thoracic pathologies, and how did the device perform across these specific subgroups?; How does the MONAI framework contribute to the algorithm's architecture and performance, and are there plans to update the non-adaptive model as new data or improved machine learning techniques become available?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CT Cardiomegaly - Innolitics, LLC | ESL FDA AI Device Intelligence