Medscape Medical NewsAll articles

MAGNETOM Cima.X Fit

Siemens Medical Solutions USA, Inc. • Radiology • 02/29/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The MAGNETOM Cima.X Fit is an advanced magnetic resonance diagnostic device intended to produce detailed anatomical and functional images for diagnostic support, featuring the syngo MR XA61A software platform and updated hardware components. Its operational methodology combines fundamental magnetic resonance principles with innovative technologies like AI-driven image reconstruction (e.g., Deep Resolve Boost), advanced sequences such as MR Fingerprinting, and motion reduction techniques like SAMER, all validated through rigorous nonclinical testing and supported by relevant clinical publications for specific applications.

Summary

The MAGNETOM Cima.X Fit, equipped with syngo MR XA61A software, is a magnetic resonance diagnostic device (MRDD) designed to generate a comprehensive range of images, including cross-sectional (transverse, sagittal, coronal, oblique) and spectroscopic views, to visualize the internal structure and function of the head, body, or extremities. Its intended use includes deriving physical parameters from these images and spectra to assist physicians in diagnosis, with the option of using contrast agents and supporting imaging during MR-compatible interventional procedures. The system features new hardware components like a 3D camera and modified elements such as the gradient coil, body coil, host computers, and cooling system, all integrated to enhance its diagnostic capabilities. This device introduces several new and modified software applications, notably leveraging artificial intelligence for image processing. Key innovations include 'Deep Resolve Boost' for HASTE and EPI Diffusion sequences, 'Deep Resolve Sharp,' 'Open Recon' for customizable reconstruction, 'Ghost reduction (DPG),' 'SAMER' for motion correction, and 'MR Fingerprinting.' The system's performance and safety were validated through extensive nonclinical testing, encompassing software verification, image quality assessments using sample clinical images, hardware bench tests, and adherence to safety standards. AI features were trained and validated on large datasets covering a broad range of body parts and contrasts, demonstrating improvements in image metrics such as PSNR and SSIM, and evaluated through visual comparisons for aspects like aliasing artifacts, image sharpness, and denoising levels, though specific demographic data for AI training was not recorded due to privacy reasons; no new clinical tests were conducted, but relevant clinical publications were referenced for specific features.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MAGNETOM Cima.X FitMagnetic Resonance Diagnostic Devicesyngo MR XA61ADeep Resolve BoostAI Image ReconstructionDiagnostic ImagingNonclinical ValidationMR FingerprintingGradient CoilSAMER Motion Reduction

Device Metadata

Submission Number
K232765
Company
Siemens Medical Solutions USA, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the performance of the new 'Deep Resolve Boost EPI Diffusion' and 'Deep Resolve Boost HASTE' features, particularly regarding image quality and diagnostic accuracy, compare quantitatively against traditional reconstruction methods in diverse patient populations?; What is the specific impact of the modified gradient coil and body coil on image signal-to-noise ratio (SNR) and spatial resolution, especially for advanced applications like MR Fingerprinting?; Could the 'Open Recon' platform be detailed further in terms of its flexibility for researchers to implement custom reconstruction algorithms, and what are the computational overheads associated with it?; Given the reliance on AI for features like Deep Resolve, what strategies are in place to monitor and mitigate potential biases in the AI models, especially since demographic data (gender, age, ethnicity) was not recorded during the collection of training/validation datasets?; How does the 'SAMER' (Scout accelerated motion estimation and reduction) feature perform in real-world clinical scenarios with significant patient motion, and what are its limitations compared to other motion correction techniques?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score55/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials(hardware, camera)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, HBOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
MAGNETOM Cima.X Fit - Siemens Medical Solutions USA, Inc. | ESL FDA AI Device Intelligence