Medscape Medical NewsAll articles

uOmnispace.MR

Shanghai United Imaging Healthcare Co., Ltd. • Radiology • 04/17/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

uOmnispace.MR is an advanced medical image post-processing software designed to enhance diagnostic capabilities by providing a comprehensive suite of tools for viewing, manipulating, and quantitatively analyzing MR images across various anatomical regions and physiological functions. Its methodology incorporates sophisticated algorithms, including AI-driven segmentation for cardiac analysis and specialized modules for spectroscopy, perfusion, and dynamic studies, validated to ensure accurate and reliable image evaluation for clinical interpretation.

Summary

uOmnispace.MR is a comprehensive medical image post-processing software designed for viewing, manipulating, evaluating, and analyzing Magnetic Resonance (MR) images within healthcare settings. It operates on the uOmnispace platform and can function independently or with other cleared applications, supporting interpretation and evaluation of examinations. The software includes a suite of specialized tools tailored for diverse clinical needs: Stitching for creating full-format images from overlapping MR volumes; Dynamic for general time-course study post-processing; MRS (MR Spectroscopy) for evaluating molecular constitution and spatial distribution of cell metabolism using SVS and CSI data; MAPs for applying arithmetic and statistical functions to grayscale values for evaluating dynamic processes; Breast Evaluation for calculating parameter maps from contrast-enhanced time-course images; Brain Perfusion for visualizing temporal variations in dynamic susceptibility time series; Vessel Analysis for MR vascular image assessment; DCE analysis for dynamic contrast-enhanced MRI evaluation; United Neuro for neurological image analysis; Cardiac Function for functional analysis of cardiac MR images; and Flow Analysis for evaluating flow in MR images. The uOmnispace.MR's methodology relies on advanced image processing algorithms, including but not limited to motion correction, series registration, parametric mapping (such as T1rho and Signal Enhancement Ratio), and segmentation techniques, specific to each of its applications. A key scientific component is the MR Cardiac Function module, which incorporates a deep learning-based AI algorithm for automatic left and right ventricular contour segmentation. Performance results from software verification and validation testing demonstrated the device's safety and efficacy. Specifically, new parameters and algorithms such as SER in MR Breast Evaluation, T1rho in MR MAPs, and semi-automatic contour segmentation with additional output parameters (mean pressure gradient, peak pressure gradient) in MR Flow Analysis were successfully validated. The AI-driven ventricular segmentation algorithm underwent rigorous evaluation using 114 diverse patient datasets, achieving a Dice coefficient of 1.00 when compared to a predicate device, indicating high consistency and accuracy. This validation was supported by ground truth annotations from experienced cardiologists and confirmed the independence of training and testing data.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MR Image ProcessingPost-processing SoftwareCardiac Function AnalysisMR Spectroscopy (MRS)Brain PerfusionVessel AnalysisDynamic Contrast-Enhanced (DCE) MRIAI AlgorithmVentricular SegmentationParametric Mapping

Device Metadata

Submission Number
K233186
Company
Shanghai United Imaging Healthcare Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation|Analysis
AI Subclass
image enhancement|quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the deep learning-based automatic ventricular segmentation algorithm in uOmnispace.MR Cardiac Function compare to manual segmentation by expert clinicians in terms of accuracy and time-efficiency across various pathologies and image qualities?; What specific image processing techniques are employed by the uOmnispace.MR MAPs application for T1rho calculation, and how do these results correlate with histological findings or other quantitative MRI biomarkers?; Can the uOmnispace.MR Brain Perfusion application differentiate between different causes of perfusion abnormalities (e.g., stroke, tumor, inflammation), and what is its sensitivity and specificity for detecting subtle perfusion changes?; For the uOmnispace.MR MRS module, what is the range of detectable metabolites, and how does the software handle potential artifacts or signal-to-noise limitations in SVS and CSI data acquisition from different MR scanner vendors?; Considering the addition of semi-automatic contour segmentation and new pressure gradient parameters in MR Flow Analysis, what is the demonstrated impact on inter-observer and intra-observer variability in quantitative flow measurements?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, ground truth, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
uOmnispace.MR - Shanghai United Imaging Healthcare Co., Ltd. | ESL FDA AI Device Intelligence