Medscape Medical NewsAll articles

AVIEW CAC

Coreline Soft Co., Ltd. • Radiology • 03/29/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

AVIEW CAC is a software application that performs quantitative analysis of coronary artery calcification from non-contrast, non-gated chest CT scans by employing deep learning for automated artery segmentation and Agatston score calculation. It is intended to assist healthcare professionals in risk stratification by providing calcium scores and percentile-based risk categories, with current validated use limited to CT scans from General Electric equipment.

Summary

AVIEW CAC is a medical image processing software designed for healthcare professionals, such as radiologists and cardiologists, to conduct quantitative analysis of calcified plaques within the coronary arteries. It utilizes non-contrast, non-gated Chest CT scans from adult patients aged 40 and older. The system primarily calculates the Agatston score for coronary artery calcification by segmenting and evaluating the right and left coronary arteries. Furthermore, it offers risk stratification based on the calculated calcium score, patient gender, and age, referencing established medical guidelines. This tool aims to support clinical assessment by providing quantitative data derived from existing CT studies. The software operates on a personal computer and employs the DICOM 3.0 standard for managing medical images, including functions for reading, manipulating, analyzing, post-processing, storing, and transferring data. It facilitates access through mobile devices and Chrome browsers for on-premises data sets. The core technology involves automatic segmentation of coronary arteries and calcified regions, reportedly using deep learning algorithms, to determine the Agatston score. Performance evaluations, based on non-clinical testing with 150 non-gated chest CT cases, demonstrated high intraclass correlation coefficients (ICC) for Agatston scores when compared to ground truth (Total ICC: 0.896, LCA: 0.927, RCA: 0.840) and a predicate device. However, the device's use is specifically validated for CT scans acquired using General Electric (GE) equipment.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Coronary Artery CalcificationAgatston ScoreChest CTQuantitative AnalysisImage Processing SoftwareDICOMRisk StratificationDeep LearningNon-contrast CTGE CT Scanners

Device Metadata

Submission Number
K233211
Company
Coreline Soft Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the deep learning algorithm specifically identify and segment calcified plaques in non-gated chest CT scans, and what is its performance compared to manual segmentation or other automated methods?; What are the specific sensitivity, specificity, and accuracy of AVIEW CAC for detecting various Agatston score categories (e.g., 0, 1-10, 11-100, 101-400, >400) on non-contrast, non-gated chest CTs?; Given the device's limitation to GE CT scanners, what are the technical challenges and validation requirements for expanding its use to CT scanners from other manufacturers?; How does AVIEW CAC's performance in Agatston scoring vary with different CT acquisition parameters (e.g., slice thickness, radiation dose) within the GE scanner ecosystem?; What impact does the use of AVIEW CAC for opportunistic screening on non-gated chest CTs have on downstream clinical decision-making and patient outcomes compared to traditional cardiac-gated CT calcium scoring?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, data set, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
AVIEW CAC - Coreline Soft Co., Ltd. | ESL FDA AI Device Intelligence