Rapid (6.0)
iSchemaView, Inc. • Radiology • 01/16/2024
Device Purpose
The iSchemaView Rapid (6.0) platform is a medical image management and processing system designed to assist clinicians in rapidly analyzing CT and MRI scans for diagnosing conditions, with a key indication for selecting acute stroke patients for endovascular thrombectomy. It operates by processing DICOM-compliant image data through specialized modules (e.g., CTP, DWI, CTA) to visualize and quantify tissue characteristics such as perfusion, diffusion, and vessel occlusion, streamlining complex analyses in time-critical situations.
Summary
The iSchemaView Rapid (6.0) is an advanced software package designed for medical image management and processing, intended for use by trained professionals like physicians and medical technicians. Its primary purpose is to facilitate the visualization, quantification, analysis, and reporting of tissue changes using digital images from CT and MRI diagnostic systems, thereby aiding in diagnosis. A significant application of Rapid CT-Perfusion and MR-Perfusion modules is to assist physicians in selecting acute stroke patients, specifically those with known intracranial internal carotid artery or proximal middle cerebral artery occlusions, for endovascular thrombectomy, provided they meet clinical requirements and have no contraindications such as poor bolus quality, excessive motion artifacts, or hemorrhage. The Rapid platform functions as a Software as a Medical Device (SaMD), installable on a customer's server or accessible as a virtual system, in on-premises or hybrid (on-premises/cloud) configurations. It processes DICOM-compliant medical image data acquired from various sources, automatically identifying the scanning modality to apply suitable processing modules like Rapid CTP/MRP, DWI, CTA, and ASPECTS for analyses including volumetry, time-intensity plots, and mismatch measurements. The system is engineered to streamline time-consuming image processing tasks with minimal user interaction, featuring an image processing engine and a central iSchemaView Server for encrypted data storage and secure access, supporting critical decision-making in clinical workflows, particularly for time-sensitive conditions.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the Rapid platform's algorithm for selecting acute stroke patients for endovascular thrombectomy account for variations in imaging protocols or scanner types across different institutions?; What are the specific performance metrics (e.g., sensitivity, specificity, processing time) of the individual modules like Rapid CTA or Rapid ICH in real-world clinical settings beyond the provided validation data?; How does the hybrid (on-premises/cloud) configuration impact data security, processing speed, and integration with existing hospital IT infrastructure compared to a fully on-premises deployment?; Can the Rapid platform quantify the evolution of ischemic changes over time by comparing serial scans, and what is the reliability of such longitudinal analysis?; Beyond identifying contraindications like hemorrhage or poor bolus quality, does the software provide any quantitative assessment of scan quality to guide reprocessing or reacquisition?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of SBOM, ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.
• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly