Ceevra Reveal 3+
Ceevra, Inc. • Radiology • 12/05/2023
Device Purpose
Ceevra Reveal 3+ is a medical image processing software that transforms CT and MR scans into interactive 3D anatomical models for enhanced preoperative planning and intraoperative visualization. It utilizes machine learning for automated segmentation in adults and provides quantitative measurement tools, with performance validated through rigorous testing on diverse patient data and phantom models.
Summary
Ceevra Reveal 3+ is an advanced software medical device designed to assist healthcare professionals by generating and displaying interactive three-dimensional (3D) images derived from patient CT and MR scans. The system involves two primary functions: company personnel use the software to create these 3D visualizations, which clinicians subsequently access and interact with via dedicated mobile or desktop applications, external displays, or compatible virtual reality (VR) headsets. This interactive visualization capability supports preoperative surgical planning and enables intraoperative display of anatomical models, allowing clinicians to rotate, zoom, pan, selectively show or hide structures, and notably, utilize newly incorporated features for quantitative measurements like volume, diameter, and inter-structural distances. The software leverages machine learning (ML) and computer vision algorithms to perform preliminary segmentation of normal anatomy, specifically for adult patients aged 22 and older; images for younger individuals or those of unknown age are processed without ML involvement. The robustness of its four ML models was extensively validated using 141 distinct patient imaging studies, ensuring data diversity in terms of patient demographics and scanner manufacturers (GE, Siemens, Toshiba, Philips), and maintaining strict separation between training and testing datasets. Performance assessments, using Sørensen–Dice coefficient (DSC) and Hausdorff distance (HD-95), yielded strong results for various anatomical structures, including prostate (0.87 DSC), bladder (0.90 DSC), neurovascular bundles (7.8 mm HD-95), kidneys (0.87-0.89 DSC), and major arteries and veins (0.81-0.87 DSC). Furthermore, the accuracy of the quantitative measurement features was confirmed through tests on phantom data and actual patient studies, demonstrating a mean difference within +/- 10%.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of the machine learning segmentation algorithms in Ceevra Reveal 3+ vary across different CT/MR scanner manufacturers and imaging protocols beyond those tested?; What is the specific methodology used by Ceevra personnel to generate the 3D images, and what level of manual intervention or quality control is involved before clinicians access them?; For the new quantitative measurement features, what is the range of error observed, and how does this compare to manual measurements or other established measurement tools in clinical practice?; How does the intraoperative display functionality integrate into existing surgical workflows, and what is the latency or update speed when interacting with 3D models in real-time during a procedure?; Given that machine learning is only used for patients 22 and over, what are the differences in image quality, segmentation accuracy, or utility for preoperative planning when ML-assisted segmentation is not employed for younger patients?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly