RAYDENT SW
RAY Co., Ltd. • Dental • 05/16/2024
Device Purpose
RAYDENT SW is a comprehensive dental software solution that utilizes patient-derived 2D and 3D imaging data, including AI/ML-driven analysis, to enable dental professionals to perform detailed treatment planning and design a range of custom orthodontic and prosthetic devices. Its methodology centers on creating virtual simulations and 3D models for applications such as clear aligner fabrication and crown design, aiming to enhance the precision and efficiency of dental treatments.
Summary
RAYDENT SW, developed by Ray Co., Ltd., is a specialized software designed to assist dental professionals in comprehensive patient treatment planning and the design of various dental treatment devices. Its core methodology involves utilizing patient-specific images, including DICOM, 2D, and 3D formats (PLY, OBJ, STL), acquired from compatible scanners. The software processes this data to perform simulations, enabling clinicians to reference and refine treatment plans. It functions as a critical tool for creating digital designs of both prosthetic devices, such as veneers, crowns, bridges, and inlays/onlays, as well as orthodontic devices like clear aligners, based on 3D mesh data of the patient's maxilla and mandible. The underlying science of RAYDENT SW encompasses a suite of functionalities including the acquisition of oral topography image data, creation, alignment, measurement, and analysis of 3D virtual dental models. It incorporates features like tooth segmentation, occlusal definition, Bolton analysis, and Interproximal Reduction (IPR) planning. The software also supports orthodontic treatment simulation, virtual appliance design, and specific prosthesis design capabilities. While clinical testing was not performed, the software underwent rigorous software, hardware, and integration verification and validation testing, with all test results reportedly demonstrating its functional capabilities and meeting design specifications. The system is noted as being AI/ML-enabled, suggesting advanced algorithms for its analytical and design functions.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific AI/ML algorithms are utilized in RAYDENT SW for features like tooth segmentation or treatment outcome prediction, and how have these been validated for accuracy and bias?; Can RAYDENT SW integrate with a broad range of intraoral and CBCT scanners, or is its compatibility limited to specific proprietary imaging equipment, and what are the data import/export capabilities beyond PLY, OBJ, STL, and DICOM?; How does the software ensure the accuracy of the 3D mesh data generated from patient images, and what tools are provided for clinicians to verify and adjust these models before proceeding with treatment planning or device design?; What is the typical learning curve for dental professionals to become proficient in using RAYDENT SW, especially concerning its advanced orthodontic simulation and prosthetic design modules, and what training resources are provided by Ray Co., Ltd.?; Given that RAYDENT SW designs both orthodontic and prosthetic devices, what are the specific workflow differences within the software for these two distinct types of treatments, and how does it manage the interplay if a patient requires both?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, HBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly