CorVista System with PH Add-On

Analytics for Life, Inc. • Cardiovascular • 04/05/2024

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The CorVista® System with PH Add-On is a non-invasive diagnostic aid that employs a machine learning algorithm to analyze synchronously acquired cardiac electrical (VCG) and hemodynamic (PPG) signals, along with patient demographics, to provide a binary output indicating the likelihood of elevated mean pulmonary arterial pressure. This system is intended for use by healthcare providers to assist in the evaluation of adult patients presenting with cardiovascular symptoms suggestive of pulmonary hypertension, complementing their overall clinical assessment.

Summary

The CorVista® System with PH Add-On is a non-invasive medical device system comprising hardware (including a Seven-Channel Lead Set, PPG Sensor, and a Capture Device/Tablet) and software components, designed to aid healthcare providers in assessing patients with cardiovascular symptoms for the likelihood of elevated mean pulmonary arterial pressure (mPAP), an indicator of pulmonary hypertension. The system functions by synchronously acquiring cardiac electrical signals through vectorcardiography (VCG) and hemodynamic signals via photoplethysmography (PPG). These physiological signals, along with patient demographics, are analyzed by a proprietary machine learning-based algorithm within the PH Add-On module, which then generates a binary output. This output is presented to the healthcare provider via a tablet, mobile app, or a secure web-based portal, serving as an adjunctive tool to be used in conjunction with clinical judgment, patient signs, symptoms, and history. The clinical performance of the CorVista System with PH Add-On was evaluated in a prospective, multicenter study involving 386 symptomatic adult subjects. The device's output was compared against established clinical outcomes: elevated mPAP (≥ 25mmHg confirmed by invasive right heart catheterization) for sensitivity testing, and non-elevated mPAP (determined by core lab adjudicated Transthoracic Echocardiogram) for specificity testing. The study demonstrated 82% sensitivity and 92% specificity, with a negative predictive value (NPV) greater than 99% and an area under the receiver operating characteristic curve (AUC-ROC) of 0.95. A secondary endpoint analysis at an mPAP threshold of ≥ 21 mmHg showed an AUC-ROC of 0.93 and 78% sensitivity. Additional studies confirmed the repeatability and reproducibility of the PH score generated by the system.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary HypertensionmPAP (mean pulmonary arterial pressure)Machine LearningPhysiological SignalsNon-invasiveDiagnostic AidVectorcardiography (VCG)Photoplethysmography (PPG)SensitivitySpecificity

Device Metadata

Submission Number
K233666
Company
Analytics for Life, Inc.
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
diagnosis

Relevant Clinical Questions

  • Q1. What is the performance of the CorVista System with PH Add-On in diverse patient populations, particularly those with comorbidities that might also present with similar cardiovascular symptoms (e.g., COPD, left heart disease)?; How does the algorithm's reliance on patient demographics influence its predictive accuracy, and are there specific demographic profiles where its performance varies significantly?; Can the system provide a continuous or multi-level likelihood score rather than a binary output, potentially offering more nuanced information for clinical decision-making?; What are the specific VCG and PPG features identified by the machine learning algorithm as most indicative of elevated mean pulmonary arterial pressure?; How was the core lab adjudication of Transthoracic Echocardiograms (TTE) standardized to ensure consistency in determining non-elevated mPAP for the specificity analysis, and what was the inter-observer variability?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score40/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software component)
✓ Detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials(hardware, sensor)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM, HBOM detected in AI-generated device summary.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CorVista System with PH Add-On - Analytics for Life, Inc. | ESL FDA AI Device Intelligence