Medscape Medical NewsAll articles

Voluson Signature 20, Voluson Signature 18

GE Medical Systems Ultrasound and Primary care Diagnostics, • Radiology • 03/07/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Voluson Signature 20 and Voluson Signature 18 are diagnostic ultrasound systems designed for comprehensive, multi-application imaging, with a particular focus on OB/GYN, utilizing a range of established and advanced ultrasound technologies including 3D/4D imaging, Doppler modalities, and Shearwave Elastography. These systems enhance clinical workflow through a mobile console, diverse transducer compatibility, numerous automated software features migrated from predicate devices, and new functionalities like voice command, ensuring broad diagnostic utility across various medical specialties.

Summary

The Voluson Signature 20 and Voluson Signature 18 are advanced diagnostic ultrasound systems designed for general-purpose medical imaging, with a specialization in obstetrics/gynecology (OB/GYN) applications, including real-time 3D/4D acquisition. These mobile console systems feature a user-friendly interface with a keyboard, touch panel, and high-resolution display, facilitating comprehensive image analysis, networking, and DICOM capabilities. They are intended for use by qualified healthcare professionals in hospital or clinic settings across a wide array of clinical applications, such as fetal/obstetrics, abdominal, pediatric, small organs (e.g., breast, testes, thyroid), cephalic (neonatal and adult), cardiac (adult and pediatric), peripheral vascular, musculoskeletal, transrectal, and transvaginal imaging. The systems employ established ultrasound technology, utilizing various transducers (linear, curved linear, matrix phased array) to support numerous imaging modes. These include B-mode, M-mode, Doppler (PW, CW, Color, Power, Tissue), HD-Flow, Harmonic Imaging, 3D/4D imaging, Elastography (including Shearwave), B-Flow, and Contrast imaging. Key differentiating features include migrated software functionalities from predicate devices such as Fetal Heart Support, SonoAVCfollicle, Shearwave Elastography, Perspective Rendering, SonoLyst, and Vscan Air CL Probe Support, alongside a new voice command feature. The device's design and safety are supported by extensive non-clinical testing, including evaluations for acoustic output, biocompatibility, and conformance to numerous medical device safety standards, ensuring its performance is comparable to legally marketed predicate devices.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Diagnostic UltrasoundVoluson Signature3D/4D ImagingOB/GYNShearwave ElastographyDoppler ImagingMulti-applicationTransducer TechnologyDICOMVoice Command

Device Metadata

Submission Number
K233692
Company
GE Medical Systems Ultrasound and Primary care Diagnostics,
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the new "Voice Command" feature compare to manual operation in terms of workflow efficiency and user satisfaction in diverse clinical settings (e.g., OB/GYN vs. cardiac)?; What are the specific quantitative improvements, if any, in image quality or diagnostic accuracy provided by the migrated software features (e.g., Shadow Reduction, FlowProfiles, Advanced STIC) compared to the predicate devices they originated from?; Could the integration of "Shearwave Elastography" across the Voluson Signature series expand its utility in applications beyond those previously established, such as early detection of specific fetal or gynecological conditions?; Considering the wide range of supported transducers and imaging modes, are there specific transducer-mode combinations where the Voluson Signature 20/18 demonstrates superior performance or offers unique diagnostic capabilities compared to the primary predicate (Voluson S series)?; What is the impact of the "Vscan Air CL Probe Support" on the system's portability and point-of-care usability, and are there any trade-offs in image quality or functionality when using this wireless probe compared to traditional cabled transducers?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network, connectivity, wireless)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Voluson Signature 20, Voluson Signature 18 - GE Medical Systems Ultrasound and Primary care Diagnostics, | ESL FDA AI Device Intelligence