Medscape Medical NewsAll articles

Revolution Ascend Sliding

GE Hangwei Medical Systems Co., Ltd. • Radiology • 02/22/2024

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Revolution Ascend Sliding system is an advanced computed tomography device engineered to enhance clinical workflow by employing a gantry that moves on rails around a stationary patient, thereby facilitating integrated in-room imaging and procedures. Its methodology relies on X-ray transmission data acquisition across multiple planes and subsequent computer reconstruction, maintaining the core imaging science and performance of its predicate while introducing an innovative patient-gantry interaction specifically beneficial for interventional radiology and radiation oncology applications.

Summary

The Revolution Ascend Sliding is a computed tomography (CT) X-ray system designed for head, whole-body, cardiac, and vascular imaging applications across all patient ages. It comprises a gantry, a transporter system, an operator console with a host computer, a power distribution unit, and associated hardware/software for image acquisition and reconstruction. The system generates cross-sectional images by computer reconstruction of X-ray transmission data obtained from various angles and planes, supporting modes such as Axial, Cine, Helical (Volumetric), Cardiac, and Gated acquisitions, with or without contrast media. It also includes capabilities for signal analysis, image display, and post-processing to produce images in diverse trans-axial and reformatted planes, aiding in the diagnosis, planning, guidance, and monitoring of medical conditions and therapies. The primary technological distinction of the Revolution Ascend Sliding from its predicate device is its gantry mobility. Instead of a traditional moving patient table, this system features a gantry mounted on a transporter that allows linear movement on rails. This design enables the gantry to scan the patient, who remains on a stationary support, thereby facilitating an improved clinical workflow, particularly in interventional radiology and radiation oncology settings. This innovation allows for both CT imaging and treatment procedures to occur in the same room without requiring patient transfer, while maintaining identical intended use, indications for use, and equivalent imaging performance and quality specifications to the predicate device. Key components include a 75cm bore, Performix 40 Plus X-Ray Tube, JEDI60DC High Voltage Generator, and Merc40H detector, though the physical gantry tilt feature is disabled.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Computed Tomography (CT)Sliding GantryTransporter SystemX-ray ImagingImage ReconstructionInterventional RadiologyRadiation OncologyWhole-body ImagingStationary Patient SupportClinical Workflow Enhancement

Device Metadata

Submission Number
K233749
Company
GE Hangwei Medical Systems Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
acquisition guidance

Relevant Clinical Questions

  • Q1. What are the specific mechanical and operational differences in the transporter rail system of the Revolution Ascend Sliding compared to the gantry movement mechanisms in the reference device (K091673), and how do these impact long-term reliability and maintenance schedules?; How does the stationary patient setup combined with the moving gantry affect image registration accuracy and potential for motion artifacts during procedures requiring precise targeting, such as biopsies or radiotherapy planning, compared to traditional moving table systems?; What are the radiation safety implications, specifically concerning scatter radiation patterns and occupational dose to clinical staff, resulting from the sliding gantry design during combined imaging and interventional procedures within the CT suite?; Given that the physical tilt feature of the gantry is disabled in the Revolution Ascend Sliding, what alternative imaging techniques or software-based reconstruction methods are employed to achieve oblique or angled views, and how does this affect diagnostic image quality for specific anatomical regions or clinical scenarios?; What ergonomic assessments and quantitative workflow studies were conducted to validate the claimed improvements in clinical efficiency for interventional radiology and radiation oncology, particularly concerning procedure time, patient handling, and room turnover?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials(hardware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SaaSBOM, HBOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, ML-BOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Revolution Ascend Sliding - GE Hangwei Medical Systems Co., Ltd. | ESL FDA AI Device Intelligence