Medscape Medical NewsAll articles

AI-Rad Companion (Pulmonary)

Siemens Healthcare GmbH • Radiology • 03/21/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

AI-Rad Companion (Pulmonary) SW version VA40 is an advanced image processing software designed to support clinicians in the assessment of lung diseases by providing quantitative and qualitative analysis of CT DICOM images. It utilizes machine learning and deep learning algorithms for functionalities such as lung and lobe segmentation, identification of Hounsfield value alterations, and comprehensive segmentation and follow-up of both solid and sub-solid pulmonary nodules.

Summary

AI-Rad Companion (Pulmonary) SW version VA40 is image processing software designed to assist clinicians in evaluating lung diseases using previously acquired Computed Tomography (CT) DICOM images. Employing machine learning and deep learning algorithms, it provides quantitative and qualitative analysis, including segmentation and measurement of lungs, lung lobes, and both solid and sub-solid lung nodules. The software identifies regions with altered Hounsfield values, dedicates nodules to specific lobes, correlates current findings with prior scans to assess changes, and can interface with external CAD systems. It is intended for use with adult patients (22 years and older) and has been validated with data from Siemens Healthineers, GE Healthcare, and Philips CT scanners, functioning as an adjunct tool for qualified medical professionals and not replacing their judgment. A key enhancement in this version (VA40) is the introduction of sub-solid lung nodule segmentation, expanding its lesion analysis capabilities beyond the previous version which primarily handled solid nodules. The software's performance was validated through non-clinical testing against its predicate device, using data from 527 subjects across the United States and Germany. Results demonstrated significantly better performance than the predicate for existing solid and calcified nodule types, as indicated by a higher average DICE coefficient. Furthermore, the new sub-solid nodule segmentation feature showed superior DICE coefficient performance compared to the predicate's solid nodule segmentation. The validation process included rigorous ground truth annotation by experienced radiologists and ensured independence between training and testing datasets, confirming the software's reliability and improved accuracy.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Lung Nodule SegmentationSub-solid NodulesComputed Tomography (CT)DICOMMachine LearningDeep LearningImage Processing SoftwareQuantitative AnalysisHounsfield ValuesLesion Follow-up

Device Metadata

Submission Number
K233753
Company
Siemens Healthcare GmbH
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the algorithm differentiate between various sub-types of sub-solid nodules (e.g., pure ground-glass, part-solid), and what is its performance accuracy for each sub-type?; What specific machine learning/deep learning architectures are employed for the lung lobe and nodule segmentation tasks, and how were they optimized for CT images from different vendors and reconstruction techniques?; The validation data included low-dose and conventional-dose CT scans; are there statistically significant differences in the software's performance between these two dose levels, particularly for small or sub-solid nodules?; Regarding lesion follow-up, what is the minimum detectable change in nodule size or volume that the software can reliably quantify, and how does this compare to inter-observer variability among radiologists?; Given the validation on images from Siemens, GE, and Philips, what is the anticipated performance or potential limitations when processing CT images from other manufacturers or newer reconstruction algorithms not included in the validation set?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.