Medscape Medical NewsAll articles

EPIQ Series Diagnostic Ultrasound System, Affiniti Series Diagnostic Ultrasound System

Philips Ultrasound LLC • Radiology • 02/13/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Smart Doppler View ID is an AI-driven software feature for Philips EPIQ and Affiniti ultrasound systems designed to streamline adult cardiac TTE exams by automatically selecting the appropriate Doppler calculation package group from an acquired spectrum. Its methodology relies on a trained algorithm that analyzes Doppler waveforms to suggest one of six cardiac views, demonstrated to have 97.5% accuracy, thereby enhancing workflow efficiency while allowing for user override.

Summary

The Philips EPIQ and Affiniti Series Diagnostic Ultrasound Systems introduce the Smart Doppler View ID, a software feature enhancing workflow in adult cardiac transthoracic echocardiography (TTE). It automates the selection of Doppler measurement calculation package groups on the system's touch screen by employing an artificial intelligence-based algorithm to analyze the user-acquired Doppler spectrum, thereby suggesting the relevant package group and streamlining subsequent measurements, a task previously done manually. This feature supports six specific Doppler calculation package groups (Aortic Valve, Mitral Valve, Tricuspid Valve, Pulmonic Valve, Venous Flow, and TDI Velocity & Ratio) and is a software-only update compatible with existing Philips transducers and systems on software version 11.0 or higher. Performance evaluation via a study with 1100 TTE cardiac clips from 400 subjects showed the AI algorithm achieved 97.5% accuracy in identifying the correct calculation package group compared to ground truth established by experienced clinicians, while still allowing users to manually override suggestions.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

UltrasoundDopplerArtificial IntelligenceWorkflow AutomationCardiac ImagingEchocardiographyCalculation PackageSmart Doppler View IDTransthoracic EchoAlgorithm Accuracy

Device Metadata

Submission Number
K233788
Company
Philips Ultrasound LLC
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the Smart Doppler View ID algorithm differentiate between complex or atypical Doppler spectra that might correspond to multiple valvular pathologies or unusual flow patterns?; What is the learning curve for sonographers to effectively integrate the Smart Doppler View ID into their existing workflow, and what is the typical rate of manual override observed in real-world clinical settings post-implementation?; Are there specific patient populations, cardiac conditions, or image qualities where the algorithm's 97.5% accuracy might be lower, and what mechanisms are in place to alert users in such scenarios?; Beyond the six currently supported cardiac calculation package groups, are there plans to expand the Smart Doppler View ID's capabilities to other Doppler applications or anatomical regions within echocardiography?; How does the Smart Doppler View ID algorithm handle variations in Doppler signal quality due to operator skill or patient factors, and does it provide feedback on spectrum quality for optimal AI processing?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials(algorithm, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM detected in AI-generated device summary.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EPIQ Series Diagnostic Ultrasound System, Affiniti Series Diagnostic Ultrasound System - Philips Ultrasound LLC | ESL FDA AI Device Intelligence