Device Purpose

Clarius OB AI is an AI-powered software designed to assist healthcare professionals by automatically segmenting fetal anatomy and measuring key biometric parameters from ultrasound images acquired with the Clarius Ultrasound Scanner. Its methodology relies on a deep learning algorithm validated through non-inferiority studies against expert clinicians, aiming to enhance efficiency and consistency in obstetric assessments, particularly for estimating gestational age, while allowing for user oversight and manual adjustments.

Summary

Clarius OB AI is an assistive software tool integrated into the Clarius Ultrasound App, designed for use with the Clarius Ultrasound Scanner system by trained healthcare professionals. Its purpose is to aid in obstetric ultrasound imaging by performing non-invasive, semi-automated measurements of key fetal biometric parameters on adult patients. The methodology involves a deep learning image segmentation algorithm that, upon selection of an obstetric preset (OB or Early OB), automatically detects and segments fetal anatomy (head, abdomen, femur, or whole fetus for early OB) and places calipers to measure head circumference (HC), abdominal circumference (AC), femur length (FL), bi-parietal diameter (BPD), and crown rump length (CRL). The science relies on a machine learning model trained on diverse ultrasound data to provide these measurements in B-Mode, with users retaining the ability to manually adjust the AI-generated calipers and the ultimate responsibility for clinical interpretation. The performance of Clarius OB AI was validated through non-clinical testing against relevant industry standards and extensive clinical performance testing. A retrospective clinical verification study involving 347 subjects and images from diverse international sites demonstrated that Clarius OB AI's automated measurements were non-inferior to manual measurements performed by expert clinicians, with statistically significant p-values (<2.2e-16) and high intraclass correlation (ICC of 0.99). Segmentation accuracy was confirmed with high Jaccard (range 0.73-0.94) and Dice (range 0.84-0.97) scores. A subsequent clinical validation study confirmed its usability and that it performs as intended in a representative user environment, meeting user needs for semi-automated fetal biometric measurements used in calculating fetal gestational age. The device also includes a Predetermined Change Control Plan for future AI model updates and improvements, addressing aspects like model architecture, training methods, post-processing algorithms, and compatibility with new data input sources.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Fetal biometryObstetric ultrasoundMachine learningDeep learningImage segmentationAutomated measurementGestational ageNon-inferiorityClinical validationClarius Ultrasound Scanner

Device Metadata

Submission Number
K233955
Company
Clarius Mobile Health Corp.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the Clarius OB AI deep learning model vary across different gestational age ranges, particularly at the extremes (e.g., very early OB vs. late third trimester)?; What specific image quality parameters are most critical for the Clarius OB AI to achieve optimal segmentation and measurement accuracy, and how does the system alert users to suboptimal image quality?; Given the diverse ethnic groups in the training and verification datasets, are there any performance differences or biases observed for specific fetal biometric parameters in distinct populations, and how are these addressed?; The Predetermined Change Control Plan mentions mitigating overfitting and unintended bias; what specific techniques beyond regularization and cross-validation are employed, particularly for ensuring fairness across diverse patient demographics with new data input sources?; How does the semi-automated workflow with Clarius OB AI, including the option for manual adjustment, impact overall examination time and inter-observer variability compared to fully manual measurement techniques in real-world clinical settings?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score50/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, deep learning, algorithm, dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Clarius OB AI - Clarius Mobile Health Corp. | ESL FDA AI Device Intelligence