Medscape Medical NewsAll articles

Acumen Assisted Fluid Management (AFM) Software Feature

Edwards Lifesciences, LLC • Cardiovascular • 08/02/2024

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Acumen Assisted Fluid Management (AFM) Software Feature, enhanced with an AFM Prompt Reclassifier algorithm, aims to optimize fluid therapy for surgical patients by providing refined, data-driven suggestions on fluid administration. It utilizes real-time hemodynamic data processed through a dual-algorithmic approach—a core algorithm for initial assessment and a reclassifier for enhanced accuracy—to predict and improve patient response to fluid boluses, specifically by increasing the positive predictive value of "Fluid Bolus Suggested" prompts for achieving desired changes in stroke volume.

Summary

The Acumen Assisted Fluid Management (AFM) Software Feature, developed by Edwards Lifesciences, is designed as an adjunctive open-loop fluid therapy recommender for surgical patients aged 18 and older who require advanced hemodynamic monitoring. Its core function is to provide clinicians with physiological insights into a patient's estimated response to fluid therapy and their associated hemodynamics by offering suggestions. These suggestions, based on a core AFM algorithm and presented via a graphical user interface, guide clinicians regarding a patient's physiological condition and potential response to fluid administration. However, the ultimate decision to administer a fluid bolus rests with the clinician, who must consider the patient's overall hemodynamic status, and the software's suggestions are not intended for sole therapeutic decision-making. This iteration of the Acumen AFM Software Feature introduces an AFM Prompt Reclassifier (AFM PR) algorithm, which works in conjunction with the existing core AFM algorithm. The AFM PR algorithm's purpose is to re-assess the fluid bolus recommendations generated by the core algorithm by analyzing the patient's current hemodynamics. It can either confirm the original prompt or reclassify it, for instance, changing a "Test Bolus Suggested" prompt to a "Fluid Bolus Suggested" prompt or vice versa. This acts as a secondary check, aiming to increase the likelihood that "Fluid Bolus Suggested" prompts result in the desired change in stroke volume. Performance validation using an archived dataset from a US IDE Study (307 patients, 1229 data points) demonstrated that the AFM PR algorithm improved the response rate for "Fluid Bolus Suggested" prompts, indicating enhanced optimization of the software's impact on patient hemodynamics without raising new safety or effectiveness concerns.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Fluid ManagementHemodynamicsStroke VolumeSurgical PatientsAlgorithmFluid ResponsivenessAdjunctive TherapyDecision SupportPrompt ReclassifierAdvanced Monitoring

Device Metadata

Submission Number
K233984
Company
Edwards Lifesciences, LLC
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What specific hemodynamic parameters does the core AFM algorithm primarily rely on to generate its initial fluid responsiveness prompts?; How does the AFM Prompt Reclassifier algorithm differentiate between situations warranting a "Test Bolus" versus a "Fluid Bolus," and what are the critical thresholds for reclassification?; What was the quantitative improvement in response rate for "Fluid Bolus Suggested" prompts with the addition of the AFM PR algorithm compared to the core AFM algorithm alone in the validation study?; Are there specific patient subpopulations or surgical contexts where the AFM PR algorithm demonstrates significantly higher or lower efficacy in improving fluid responsiveness predictions?; Beyond stroke volume, what other hemodynamic or physiological outcomes were monitored or considered to assess the overall impact and safety of the refined fluid administration suggestions?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Acumen Assisted Fluid Management (AFM) Software Feature - Edwards Lifesciences, LLC | ESL FDA AI Device Intelligence