Medscape Medical NewsAll articles

EFAI Bonesuite XR Bone Age Pro Assessment System (BAP-XR-100)

Ever Fortune.AI Co., Ltd. • Radiology • 06/07/2024

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EFAI Bonesuite XR Bone Age Pro Assessment System (BAP-XR-100) is a software medical device that employs deep learning techniques to analyze left-hand radiographs according to the Greulich-Pyle method, providing pediatric radiologists with a quantitative bone age assessment for patients aged 2 to 16. Its clinical utility as an adjunct diagnostic tool is supported by performance studies demonstrating high accuracy and consistency compared to expert radiologist consensus across diverse patient demographics and imaging conditions.

Summary

The EFAI Bonesuite XR Bone Age Pro Assessment System (BAP-XR-100) is a software tool designed to assist pediatric radiologists in quantifying bone age for patients aged 2 to 16 years. It utilizes deep learning algorithms to analyze 2D Posterior Anterior (PA) views of left-hand radiographs, referencing the Greulich-Pyle (GP) method for bone age estimation. The system outputs the estimated bone age in years as a standard JSON message for integration with existing Picture Archiving and Communication Systems (PACS), Radiology Information Systems (RIS), or Hospital Information Systems (HIS), and is intended as an adjunct tool, meaning its results should not solely determine diagnostic decisions; it requires input images to be clear of major bone destruction, deformity, fractures, or significant artifacts. The system's performance was validated through extensive nonclinical and clinical testing. Nonclinical evaluation involved a dataset of 26,222 cases, where Deming regression analysis demonstrated a strong correlation (intercept -0.06, slope 1.00) between the EFAI BAPXR output and ground truth established by radiologists. Clinical validation utilized 600 diverse U.S. cases (ages 2-16), independent of the training data, with ground truth determined by four U.S. board-certified pediatric radiologists. The primary endpoint, Deming regression between EFAI BAPXR output and ground truth, was successfully met (intercept -0.07, 95% CI [-0.13, -0.01]; slope 1.00, 95% CI [0.99, 1.00]). Performance data indicated that over 88% of cases had a difference of less than 0.5 years from the ground truth, and a Bland-Altman plot showed high consistency with 95% limits of agreement ranging from -0.517 to 0.743 years. Subgroup analyses further confirmed consistent and reliable performance across various genders, ages, races, clinical organizations, and X-ray equipment.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Bone Age AssessmentDeep LearningPediatric RadiologyLeft-Hand RadiographsGreulich-Pyle MethodDICOMPACS IntegrationDeming RegressionBland-Altman PlotAdjunct Diagnostic Tool

Device Metadata

Submission Number
K234042
Company
Ever Fortune.AI Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the system's performance vary in the 'Late-puberty' subgroup, where the Deming regression intercept was -1.10 and slope 1.07, compared to other age groups, and what might account for this difference?; What specific deep learning architecture is employed by the EFAI BAPXR, and how was the Greulich-Pyle method computationally interpreted and implemented for feature extraction and age estimation?; Given the requirement that images be without 'major bone destruction, deformity, fracture, excessive motion, or other major artifacts,' does the system include an automated pre-screening or quality assessment module to flag unsuitable images?; How does the system's bone age assessment time and consistency compare to manual Greulich-Pyle assessments performed by individual pediatric radiologists, considering inter-rater and intra-rater variability?; Beyond the provided subgroup analysis for X-ray manufacturers, what specific image characteristics (e.g., resolution, noise levels, contrast) influenced by different scanners have the most impact on the algorithm's accuracy, and are there calibration recommendations?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, deep learning, algorithm, dataset, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EFAI Bonesuite XR Bone Age Pro Assessment System (BAP-XR-100) - Ever Fortune.AI Co., Ltd. | ESL FDA AI Device Intelligence