EchoGo Heart Failure (2.0)
Ultromics Limited • Cardiovascular • 09/23/2024
Device Purpose
EchoGo Heart Failure (2.0) is an automated machine learning-based decision support system designed as a diagnostic aid for clinicians assessing adult patients for Heart Failure with Preserved Ejection Fraction (HFpEF). The device utilizes a convolutional neural network to analyze apical 4-chamber echocardiogram views (with ejection fraction ≥50%), providing a binary classification of HFpEF presence and an "EchoGo Score" to support clinical interpretation.
Summary
EchoGo Heart Failure (2.0) is a prescription software device that functions as an automated machine learning-based decision support system, designed to aid clinicians in diagnosing Heart Failure with Preserved Ejection Fraction (HFpEF) in adult patients (over 25 years old). It analyzes DICOM files of apical 4-chamber echocardiogram views where the patient has an ejection fraction of ≥50%. The system outputs a binary classification indicating the likelihood of HFpEF and an "EchoGo Score" (0-100%), presented with a comparative histogram against a known population, to support the clinician's assessment; however, it is not intended for sole diagnostic use. The device's core is an artificial intelligence model, specifically a convolutional neural network, which was trained on an enlarged dataset with enhanced pre-processing and data augmentation techniques. Clinical validation was performed via a retrospective case-control study involving 1,578 patients from multiple US sites, showing a sensitivity of 90.3% and specificity of 86.1% (excluding "no classification" studies), with an AUROC of 0.947. The system demonstrated 100% repeatability and high reproducibility (82.6% positive, 82.4% negative agreement), though 7.4% of analyses resulted in "No Classification."
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the EchoGo Score distribution in the provided histogram (compared against the Independent Testing Dataset) influence clinical decision-making beyond the binary classification, particularly for scores near the 50% threshold?; What specific image quality parameters or echocardiographic view variations most significantly contribute to the 7.4% "No Classification" output, and are there actionable guidelines for sonographers to optimize image acquisition for this device?; Considering the AI model was trained on more data with additional pre-processing, what was the specific incremental improvement in sensitivity, specificity, and AUROC attributable to these changes compared to the prior version's performance?; How does the device's diagnostic accuracy (sensitivity, specificity, EchoGo Score calibration) perform across diverse patient subgroups, such as those with varying severities of diastolic dysfunction, different comorbidities (e.g., hypertension, diabetes), or specific demographic factors not explicitly detailed?; What is the recommended clinical pathway or further diagnostic steps when EchoGo Heart Failure 2.0 provides a "No Classification" output, and how does this affect the overall diagnostic workflow for suspected HFpEF?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.