Medscape Medical NewsAll articles

CADDIE

Odin Medical Limited • Gastroenterology-Urology • 07/24/2024

510(k)IEC 62304 Class B§524B Cyber Device
FDA Summary PDF

Device Purpose

CADDIE is an artificial intelligence-driven, cloud-based software designed to enhance colorectal polyp detection during standard white-light colonoscopy by providing real-time visual and auditory cues to gastroenterologists. Its methodology relies on analyzing live endoscopy video feeds to identify potential lesions, aiming to improve adenoma detection rates without increasing unnecessary resections.

Summary

CADDIE is a cloud-based, artificial intelligence software system intended to aid gastroenterologists in the real-time detection of suspected colorectal polyps during standard white-light colonoscopy procedures. It functions by interfacing with the endoscopic video processor, analyzing the live video feed through its AI algorithms to identify visual characteristics consistent with colonic mucosal lesions like polyps and adenomas. When a potential lesion is detected within the endoscope's field of view, CADDIE superimposes a green square marker on the video display, accompanied by a short, low-volume sound, to draw the clinician's attention. The system also incorporates a "Cecum AI" feature, which, upon photo-documentation of cecal landmarks by the clinician, provides a reminder to check the activation status of the primary polyp detection function; CADDIE is designed for patients aged 45 and over undergoing screening and surveillance endoscopic mucosal evaluations and is not intended to replace the clinician's full evaluation or primary diagnostic interpretation. Non-clinical bench testing of CADDIE demonstrated high efficacy, with an object-level true positive rate for polyp detection of 98.27% and a frame-level false positive rate of 1.54%, alongside minimal video delay and image degradation. The Cecum AI component also showed strong performance with a frame-level true positive rate of 94.05%. A prospective, multi-center, randomized controlled clinical trial involving 841 patients confirmed CADDIE's clinical benefits, showing a statistically significant 33% increase in adenomas per colonoscopy (APC) compared to standard colonoscopy (0.82 vs 0.62) and a significant improvement in adenoma detection rate (ADR) from 35.9% to 42.9%. Importantly, the system demonstrated non-inferiority in positive percent agreement, indicating no increase in unnecessary biopsies despite heightened detection rates, and increased detection of both diminutive (≤5 mm) and large (≥10 mm) adenomas, with no CADDIE-related adverse events reported.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Colorectal polypsComputer-assisted detection (CADe)Artificial intelligence (AI)ColonoscopyEndoscopy videoReal-time detectionAdenoma detection rate (ADR)Cloud-based softwareLesion detectionGastroenterology

Device Metadata

Submission Number
K240044
Company
Odin Medical Limited
Panel
Gastroenterology-Urology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the cloud-based architecture of CADDIE impact latency and real-time performance in clinical settings with varying network conditions?; What specific AI model architectures are employed for polyp detection and Cecum AI, and how were they optimized to achieve the reported true positive and false positive rates?; Beyond adenoma detection rate (ADR) and adenomas per colonoscopy (APC), what is the impact of CADDIE on the detection rates of specific challenging polyp morphologies (e.g., flat, depressed lesions) or those in difficult-to-visualize colonic segments?; How does the "Cecum AI" reminder feature specifically influence endoscopist workflow and adherence to quality metrics like cecal intubation documentation, beyond just polyp detection activation status?; What were the key characteristics of the 415 polyps in the development dataset confirmed by resection or photo-documentation but lacking histopathology, and how might their inclusion have biased the training of the AI algorithm?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Qualifies as a cyber device under §524B (post-Dec 2023, networked)

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan✓ Detected in Summary
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset, bias, model architecture)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, network)
✓ Detected
HBOMHardware Bill of Materials(processor)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, HBOM detected in AI-generated device summary.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CADDIE - Odin Medical Limited | ESL FDA AI Device Intelligence