CAC (gated) Algorithm
BunkerHill Health • Radiology • 09/27/2024
Device Purpose
The CAC (gated) Algorithm by BunkerHill Health is a software medical device designed to quantify and categorize coronary artery calcium from ECG-gated cardiac CT scans using deep learning. Its purpose is to provide physicians with adjunctive, on-demand information, including Agatston scores and calcium segmentation, to assist in assessing cardiovascular risk in patients aged 30 and above without replacing standard diagnostic procedures.
Summary
The CAC (gated) Algorithm is a software medical device developed by BunkerHill Health, designed to assist physicians in estimating the presence and quantity of coronary artery calcium (CAC) in patients aged 30 years and older. It functions by automatically analyzing non-contrast, electrocardiogram (ECG) gated cardiac computed tomography (CT) images. The primary aim is to provide supplementary information to clinicians during their review of a patient's case, integrated into their standard workflow, to aid in the assessment of coronary artery calcification. The device utilizes deep learning algorithms to interface with compatible CT systems, processing DICOM-formatted, non-contrast ECG-gated cardiac CT images. It localizes, quantifies, and categorizes coronary artery calcification. Key outputs include the categorization of the overall coronary artery calcium burden into four Agatston score ranges (0, 1-100, 101-400, >400 Agatston units), an exact overall Agatston score, and exact Agatston scores for individual coronary arteries (Left Main, Left Anterior Descending, Left Circumflex, and Right Coronary Artery). Additionally, it generates a DICOM segmentation map of the estimated calcium burden for informational viewing; however, these outputs are intended to supplement, not replace, the original CT scans or the physician's comprehensive report. A retrospective validation study demonstrated strong performance, with a Cohen’s weighted kappa of 0.92 for agreement with ground truth in classifying cardiovascular disease risk based on Agatston score categories.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the deep learning algorithm's performance vary with different CT scanner models, slice thicknesses (up to 3mm), and acquisition protocols used for the input ECG-gated images?; What is the inter-observer variability when physicians interpret the device-generated Agatston scores and segmentation maps compared to manual or other semi-automated methods?; Beyond the four Agatston score categories, how does the device's exact Agatston score output for individual vessels (LM, LAD, LCx, RCA) correlate with clinical outcomes or aid in more granular risk stratification?; What were the specific characteristics of the 'ground truth' used in the retrospective validation study, and how was it established (e.g., expert consensus, specific software)?; How does the device handle artifacts or challenging image quality scenarios in ECG-gated CT scans, and what is its reported failure rate or need for manual correction in such cases?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly